15. 

Volume control

30

Silent Mode

Normal Mode

Loud Mode

This function can control the operating sounds so that the door can be opened and closed without disturbing others.

Setting the volume Button on “ 0 ”

Setting the volume Button on “ 1 ”

Setting the volume Button on “ 2 ”

*  In the silent mode, the alarm still operates.

Содержание GATEMAN YDR2108

Страница 1: ......

Страница 2: ...YDR2108 User Manual Keep this manual safe for future reference The functions and design of this product can be changed without notice for quality improvement...

Страница 3: ...d this lock conforms with The products warranty does not cover defects or damages arising from the door defects improper installation lack of or improper maintenance improper storage shipping and hand...

Страница 4: ...the operating instruction Keep this manual in a convenient place so that you can refer to it when necessary Do not attempt to disassemble the unit by yourself That can cause an electronic shock and pr...

Страница 5: ...function of the product Handle the unit with care Excessive force careless handling may cause product damage Do not have your card key lost or stolen Immediate re registration of all remaining keys i...

Страница 6: ...door Manual operation is also available Break in Damage alarm 80dB alarm will go off if anyone attempts to damage the lock or forces the door open Self checking The lock checks the system status and a...

Страница 7: ...forced locking Contact the key for more than 5 seconds or press Button for more than 3 seconds after entering the Security code Internal forced locking Setting it on internal forced Lock mode Contact...

Страница 8: ...2 Registering security code 3 Locking the Door from the outside 4 Unlocking the Door from the outside 5 Locking the Door From the inside 6 Unlocking the Door From the inside 7 Setting it on Manual Loc...

Страница 9: ...ld separately Lasts up to 1 year assuming product is used 10 times a day Remarks Battery life may vary depending on temperature moisture levels frequency of use and the quality of the batteries Please...

Страница 10: ...nstall on the outside of the door Identification of Product 09 Identification of Product Key reader Reset button Emergency Power Supply Terminal Sold separately Low Battery indicator LED Keypad Jammed...

Страница 11: ...Open Close Button Manual Knob Internal Forced Lock Button Menu Button Low battery indicator Register Button Deadbolt Remote control module Battery Cover 4EA 1 5V AA Alkaline Batteries Auto Manual Lock...

Страница 12: ...ntally being locked out 4 ibutton keys are provided at purchase and you can register up to 20 card keys If you lose your currently using key re register all the remaining keys to invalidate the lost k...

Страница 13: ...i bi bing sound If you hear a pik Sound the card keys are registered If you hear a ti to ti to sound the key had been already registered Check the key operation Opening the door with your card key Pre...

Страница 14: ...locked out Set a code of 4 12 digits using the number buttons 4digits 12digits 0000 000000000000 The old code is automatically deleted when registering a new code If incorrect codes are entered 5 time...

Страница 15: ...Enter your security code Enter the code you wish to register 4 12 digits Check your security code Once registration is completed make it sure to open the lock with your new security code Opening the...

Страница 16: ...utomatically within 5 seconds The door locks when touch the keypad with the palm As the automatic lock function does not work in manual lock mode make sure to check that the door is securely locked wh...

Страница 17: ...or press button Touch the keypad with the palm Enter your security code Security code Normal Confirming the lock unlocked with a pi bi bing sound Pi bi bing Confirming the door open Contact the iButto...

Страница 18: ...the door open Security Code Exposure proof Touch the keypad again or press button Exposure proof function is useful when there is danger of exposing the security code All the numbers on the keypad are...

Страница 19: ...en set on automatic lock mode The automatic lock sensor detects the door closing and locks the door automatically within 5 seconds Use manual knob on the back body Within 5 seconds Automatic lock mode...

Страница 20: ...6 Unlocking the Door from the Inside 19 Confirming the door open Press open close button on the back body How to use...

Страница 21: ...tton Setting it on Alarm Press Button Setting it off Alarm Press Button Press Button Press Button Press Button In the default setting manual lock mode doesn t ring off the alarm while using the door H...

Страница 22: ...detect the door closing and automatically locks the door in 5 seconds 21 Setting it on automatic lock mode Setting it on manual lock mode Push up the Button on Mode Manual Mode Automatic Mode Automat...

Страница 23: ...external forced lock mode In order to turn the alarm off 1 Contact your registered iButton key or 2 enter the registered security code or 3 press and hold open close button for 5 seconds In case of u...

Страница 24: ...orced lock mode on with The security code Press and hold button for about 3 seconds until external forced lock mode is set on with 3 beeps To unlock the door from the outside in external forced lock m...

Страница 25: ...code in internal forced lock mode It enhances the level of security when all users are inside of the premises Unlocked UNLOCK No iButton and keypad function from the outside in internal forced lock m...

Страница 26: ...oor after unlocking the lock with manual thumbturn In order to turn off the alarm 1 press open close button for 5 seconds or 2 contact the iButton key or 3 enter the security code In case you cannot o...

Страница 27: ...ntry is forced while the door is locked a 80dB alarm is triggered It sounds the alarm to open the lock with manual thumbturn while the door is closed If the lock is damaged on the outside the damage a...

Страница 28: ...ode Touch the keypad with the palm again or press button Enter the security code Press and hold open close button for 5 seconds Press open close button Contact the card key on the iButton key reader T...

Страница 29: ...unlocks if it detects temperature as high as 60 C 140 F The detection temperature can be different depending on the surroundings The heat alarm can be turned off by removing batteries or entering the...

Страница 30: ...regardless of this function If incorrect security codes or unregistered iButton keys are attempted 5 times in a row it will lock out for 3 minutes with the blinking LED 5 times Resume the operation au...

Страница 31: ...e This function can control the operating sounds so that the door can be opened and closed without disturbing others Setting the volume Button on 0 Setting the volume Button on 1 Setting the volume Bu...

Страница 32: ...5V AA size alkaline battery Always check and directions when inserting batteries Use the authentic alkaline batteries It is a user s responsibility for damage caused by using unauthentic batteries Ris...

Страница 33: ...minutes External Internal forced locking Starting from the left column the LED comes on from left to right to left for twice In case of emergency The LED keeps coming on to the clockwise When registe...

Страница 34: ...Check directions Confirming Installing remote control module Remote control module Required for the use of remote control Di ri ri ri ring Option Remote control module should be installed in advance t...

Страница 35: ...y depending on the installation environment Re registration automatically deletes the previously registered remote control Press menu button Press buttons Press registration button located on the fron...

Страница 36: ...istration may lengthen the battery life Deleting the remote control registration Press menu button Press buttons Deleting remote control registration Remote control registration is cancelled with a di...

Страница 37: ...the remote control and change the batteries Unlocking the door Locking the door How to use the remote control Changing the batteries Press close button and it will lock within 2 3 seconds Press open b...

Страница 38: ...ies should be replaced right away Discharged Holding a 9V battery Touch the keypad with the palm enter the security code and retouch the keypad or press button Holding a 9V battery to emergency power...

Страница 39: ...or you are not carrying it It is a user s liability to break the lock because the user did not register a security code Press reset button located the below of iButton key reader with the pin and try...

Страница 40: ...Cautions...