Table 6. Proc_Cal_004: Lift Valve Output Threshold (Continued)
2.
JOYSTICK
1.
TILT BACK
2.
AUX 1
DIRECTION A ↑
DIRECTION B ↓
3.
LIFT ↓
4.
↑ LOWER
5.
AUX 2
DIRECTION A ↑
DIRECTION B ↓
6.
TILT FORWARD
7.
SEAT ARMREST
Action 3:
SLOWLY Activate (Feather) Lift Control.....
Action 4:
Until the pressure is 0.7 MPa (100 psi) above the standby pressure. Note that the pressure reading
may oscillate. Hold control steady and.....
Action 5:
WATCH for Attachment Movement. When it first starts to move slowly, HOLD control steady and.....
Press
*
One Time while holding control.
Action 6:
STOP activating the Lift Control. LOOK at the display.
Go to the calibration step below that matches your display.
If You See.....
Result out of range
Repeat Calibration
Press
*
One Time
You Will See:
Lift Valve Output
Press
*
at Creep
Return to Action 3.
Pressure Method: Perform Actions 3, 4, and 6 again.
Visual Method: Perform Actions 3, 5, and 6 again.
If You See.....
Lower Valve Output
Press
*
at Creep
To Continue with Calibrations.....
Go to Action 2 of Proc_Cal_005.
To Quit and Save....
Step 1: Press
or
Until You See:
Lower Valve Output
Back 1 Level
Step 2: Press
*
One Time
You Will See:
Calibrations
Back 1 Level
Perform Proc_Cal_003: Save and Exit.