WARNING
Keep park brake applied, full service brake ap-
plied, and full accelerator applied during entire
time that automated transmission valve calibra-
tion is occurring.
Refer to Table 20 for the procedures on how to per-
form Proc_Cal_016: Transmission Valve Calibration.
Table 20. Proc_Cal_016B: Transmission Valve Calibration
A. TYPICAL DISPLAY WITHOUT KEY, WITH OPTIONS
B. TYPICAL DISPLAY WITH KEY, WITHOUT OPTIONS
Information:
Parking Brake and Service Brakes MUST be properly adjusted and functioning before performing
this procedure.
Perform Proc_Cal_001: Service Password Entry before proceeding.
Action:
Start Engine.
You Will See:
Main Menu
Passwords
Step 1: Press
or
Until You See:
Main Menu
Calibrations
Step 2: Press
*
One Time
You Will See:
Calibrations
Lift Valve Output
Step 3: Press
or
Until You See:
Calibrations
Calibrate Xsmn Valve
Step 4: Press
*
One Time
You Will See:
Calibrate Xsmn Valve
Press
*
to Begin
Action 1:
APPLY Parking Brake and leave on throughout process.
Action 2:
FULLY APPLY Service Brakes and HOLD during process.
Action 3:
FULLY Depress Accelerator Pedal and HOLD during process.
Action 4:
Allow for the transmission to warm up to 60°C (140°F).
Information:
This is an automated process. The Engine, Park Brake, and Service Brake must all be ON for the
process to start.
If either Parking or Service Brake is NOT applied, you will
see.....
Apply Parking Brake
Apply Service Brake
If both Parking and Service Brakes are applied, you will
see.....
Calibrate Xmsn Valve
Press
*
to Begin.
Proc_Cal_016B: Trans. Valve Calibration-Electronic and Electronic Extended
Function
8000 YRM 1134
50
Confidential/Proprietary - Do Not Copy or Duplicate