74
FT-857 Operating Manual
M
EMORY
O
PERATION
ON
“
R
EGULAR
”
M
EMORY
C
HANNELS
Most Memory operation will be conducted in the “regular” memory registers. There are 200
memory channels available for storage and recall of important frequencies.
Normal Memory Storage
1. Tune in the desired frequency, and set the operating mode and bandwidth. If this is an
FM channel, set up any required CTCSS/DCS and repeater shift configurations. Stan-
dard (default) repeater shifts do not require you to utilize the “split” frequency memory
technique, described later.
2. Press the [
FUNC
] key momentarily, then rotate the
SELECT
knob, as needed, until
Multi Function Row “b” [
MW, SKIP, TAG
] appears on the display.
3. Press the [
A
](
MW
) key momentarily to enter the “Memory Check” mode, which is used
to find an unused memory channel. The Memory Channel Number notation at the upper
left corner of the LCD will blink, and the frequency stored (if any) on the current memory
channel will be shown in the display. Rotate the
SELECT
knob to select the channel
number on which you wish to store the current frequency data.
4. If you just want to program in the frequency data, press and hold in the [
A
](
MW
) key for
one second until you hear two beeps, a second apart; the second beep confirms that the
frequency information was successfully stored. If you want to assign an Alpha-Numeric
Tag (label) to this Memory location, see the next step.
5. If you wish to assign an Alpha-Numeric Tag to this memory location, do not press and
hold in the [
A
](
MW
) key in step 4; instead, press it momentarily; the display will now
show the default Tag for the Memory Channel (“
CH-nnn
”), and a cursor will be blinking
below the “
C
.” Now follow this procedure;
•
The blinking cursor indicates that the first character is awaiting assignment of a let-
ter, number, or symbol. Rotate the
DIAL
knob to select the desired first letter in the
proposed Tag. Note that both upper and lower case letters are available.
•
Rotate the
SELECT
knob one click clockwise to move to the next character posi-
tion.
•
Rotate the
DIAL
knob to select the desired 2
nd
character, then rotate the
SELECT
knob one click clockwise to move on to the next position.
•
Continue this process until the Tag is complete. Now move quickly to the next step.
•
When the Tag is complete, press the [
A
](
MW
) key momentarily. This will complete
the storage of the frequency and Alpha-Numeric label.
M
EMORY
O
PERATION