10
Convenient Functions
VOX Operation
The VOX (Voice Over Transmit) system provides automatic transmit/receive switching
based on voice input without pressing the PTT switch in order to transmit. The optional
SSM-512B VOX Earpiece Microphone is supported.
Press and hold
the Function key
→
Press the
p
or
q
key
→
Press the Function key
(Entering the Set Mode)
(Selecting "43 VOX")
1. Press the [
p
] key or [
q
] key to select the “
VOX ON
”.
2. Press the
PTT
switch to save the setting and return to
normal operation.
•
When the VOX system is activated, the “ ” icon will
appear on the display.
Connecting to the SSM-512B VOX Earpiece Microphone, refer to the supplied SSM-512B manual
sheet.
VFO Split Mode
Two different frequencies, one for receive (VFO-A) and another for transmit (VFO-B),
may be transmitted and received (or vice versa).
Press and hold
the Function key
→
Press the
p
or
q
key
→
Press the Function key
(Entering the Set Mode)
(Selecting "42 VFO.SPL")
1. Press the [
p
] or [
q
] to select the “
VSP. ON
”.
2. Press the
PTT
switch to save the setting and return to normal operation.
3. Set VFO-A for the desired receiving (downlink) frequency.
4. Press the [
V/M
] key to set VFO-B for desired transmit (uplink) frequency.
5. Press the [
V/M
] key twice to re-establish VFO-A as the “Main” (receive) VFO.
6. When the
PTT
switch is pressed to transmit, VFO-A and VFO-B will reverse posi-
tions. Releasing the
PTT
switch, the reverse position is canceled.
Split Memory
Two different frequencies, one for receive and another for transmit, may be registered to
a memory channel.
1. Register the receive frequency to a memory channel first.
See “Registering to Memory Channels” (Operating Manual).
2. Set the transceiver to the desired transmit frequency.
3. Press and hold the [
V/M
] key.
•
A blank memory channel will be displayed automatically.