5. Warnings and indicators
5.1 YD:WARNINGS [ON | OFF]
Factory setting is ON. Globally tuns on/off all warnings described below.
5.2 YD:OVERSPEED [50..12700 | OFF]
Factory setting is OFF. To turn on the engine speed warning (revolutions exceeded the
limit), set the value in the specified range with a step of 50 RPM.
5.3 YD:HIGHTEMP [90..344 | OFF]
Factory setting is OFF. To turn on the over temperature warning, set the value in the
specified range in degrees Celsius. If a coolant temperature sensor is linked, then its
data will be used; otherwise, oil temperature data will be used. This warning can only
be issued when the engine is running.
5.4 YD:LOWVOLT [8.0 .. 33.4 | OFF]
This setting turns the low voltage warning on and OFF. Factory setting is 11.5V. This
warning can be set whether the engine is running or not. Note that the Gateway does
not send data messages (including warnings) when the engine is not running and the
ZERO_RPM setting is set to OFF (see VI.1.5, factory setting is ON).
5.5 YD:CHARGE [8.0 .. 33.4 | OFF]
Turns the battery charging indicator on and OFF on MFDs and NMEA 2000 displays.
Factory setting is 13.6V. Charging indicator is displayed only when the engine is
running.
— 25 —