![Yacht Devices YDOG-01 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/yacht-devices/ydog-01/ydog-01_user-manual_3087617018.webp)
All processes are identical to engine number programming. Note that a NMEA 2000
data field is limited to 16383 RPM and with an incorrect divider the data may be
unavailable at high revolutions (e.g., you need a divider of 4, but set the divider to 1
and NMEA 2000 data field will have an “out of range” value at 4100 RPM).
3. Algorithm selection
To enter the algorithm selection mode, click the button 3 times. The single flash in the
response sequence means algorithm 1 (provides better noise filtering, but counts up to
15000 pulses per minute), two flashes mean algorithm 2 (counts up to 70000 PPM)
and so on. Algorithms 3 and 4 are experimental and will be changed in future versions.
All processes are identical to engine number programming.
4. Reset to factory settings
To reset Device to factory settings, click the button 8 times. The Device will confirm
the command with a 1-second GREEN flash, reset the settings, and return to a normal
flashing sequence.
5. Wrong command
When the wrong number of clicks is entered (e.g. 5 or 9) and the user command is
not recognized, the Device responses with 1-second RED flash and then returns to a
normal flashing sequence.
— 18 —