1.2 YD:DEV [0..255]
Switches NMEA 2000 device’s instance to specified value. This setting is used in large
NMEA 2000 networks and does not effect the Device’s behavior.
1.3 YD:SYS [0..15]
Switches the NMEA 2000 system instance of the Device to the specified value.
This setting is used in large NMEA 2000 networks and does not affect the Device’s
behavior.
1.4 YD:PGN <pgn> [OFF | 0 | 50..60000]
Where: <pgn> is 127488, 127489 or 126993
Set transmitting interval for specified PGN, the value is in milliseconds. OFF or 0
disable periodic PGN transmission. For default transmission intervals and PGNs
description see Appendix B.
Example 1.
Set the periodic transmission interval for “Engine Parameters, Dynamic”
PGN to 1 second:
YD:PGN 127489 1000
Example 2.
Obtain the transmission interval for “Heartbeat” PGN:
YD:PGN 126993
1.5 YD:ZERO_RPM [ON|OFF]
Factory setting is ON. With the OFF value, the Device does not send messages with
engine data (PGN 127488, 127489; they also contain engine warnings and alerts)
when RPM is 0.
— 21 —