— 36 —
Syntax
Examples
Description
YD:SHUNT_CUR [1..2500]
YD:SHUNT_CUR 10
Set external shunt rated current
in amperes (1..2500 A, integer value).
Specify this value according to your
actual shunt's nominal settings.
Factory setting: 50
YD:SHUNT_VOL [50..100]
SHUNT_VOL 75
External shunt voltage drop
in millivolts (50..100 mV, integer
value). Specify this value according
to your actual shunt's nominal
settings.
Factory setting: 75
YD:TEMPERATURE
[0..252|UNKNOWN]
YD:TEMPERATURE 1
Sets NMEA 2000 temperature
instance for the battery temperature
measuring device (0..252, integer
value), don’t confuse with NMEA
2000 device instance or data type.
If no such device is present, use
UNKNOWN.
Factory setting: UNKNOWN
YD:BATTERY [0..252]
YD:BATTERY 2
Sets NMEA 2000 battery instance
of the Device (0..252, integer value),
0 for the first or single battery.
Factory setting: 0
Table 1 continued