— 30 —
Section
Parameter
Notes
EQUALIZ_
SUPPORT=NO|YES|UNKNOWN
Factory setting:
UNKNOWN
«Supports Equalization» parameter
in PGN 127513 «Battery Configuration
Status» (used for reporting only,
not for calculations).
NOMINAL_VOL=6|12|24|32|36
Factory setting: 12
Nominal voltage in PGN 127513
«Battery
Configuration
Status».
Changing this parameter will set
the charged voltage to default
value. Place this parameter before
CHARGED_VOL in configuration file.
CHEMISTRY=LEAD_ACID|LI_
ION|NICAD|ZNO|NIMH
Factory setting:
LEAD_ACID
«Battery Chemistry» parameter
in PGN 127513 «Battery Configuration
Status». Used for reporting, to choose
default values of settings and for
calculations.
TEMP_COEF=x
x — from 0.0 to 5.0, one
decimal place.
Factory setting: 0
Battery
temperature
coefficient
(capacity percent per centigrade
degree) in PGN 127513
«Battery Configuration Status». Sets
the temperature dependency of battery
capacity and is used for calculations
when temperature sensor is available.
Typical values:
1.0% for Lead Acid batteries,
0.5% for Lithium Ion batteries.
Table 1 continued