Xylem NPE Скачать руководство пользователя страница 4

4

2.1.3.

 Allow adequate space for servicing and 

ventilation.

2.1.4.

 All piping must be supported independently 

of the pump, and must “line-up” naturally.

Never draw piping into place by  

forcing the pump suction and    

discharge connections.

2.1.5.

 Avoid unnecessary fittings. Select sizes to 

keep friction losses to a minimum.

2.2.

 Close-Coupled Units

2.2.1.

 Units may be installed  horizontally, inclined 

or vertically.

Do not install with motor below 

pump. Any leakage or condensation 

will affect the motor.

2.2.2.

 Foundation must be flat and substantial to 

eliminate strain when tightening bolts. Use  

rubber mounts to minimize noise and vibra-

tion.

2.2.3.

 Tighten motor hold-down bolts before  

connecting  piping to pump.

2.3.

 Frame-Mounted Units

2.3.1.

 It is recommended that the bedplate be 

grouted to a foundation with solid footing. 

Refer to Figure 1. 

Install a pressure relief valve large enough to 

limit the system pressure below the maxi-

mum working pressure. Avoid property dam-

age or personal injury caused by incorrect 

pressure relief valve adjustment. Pipe the 

pressure relief valve discharge to a drain or 

other location so that property damage and 

flooding will not occur.

2.3.2.

 Place unit in position on wedges located at 

four points (two below approximate center 

of driver and two below approximate center 

of pump). Adjust wedges to level unit. Level 

or plumb suction and discharge flanges.

2.3.3.

 Make sure bedplate is not distorted and 

final coupling alignment can be made within 

the limits of movement of motor and by 

shimming, if necessary.

2.3.4.

 Tighten foundation bolts finger tight and 

build dam around foundation. Pour grout 

under bedplate making sure the areas under 

pump and motor feet are filled solid. Allow 

grout to harden 48 hours before fully tight-

ening foundation bolts.

2.3.5.

 Tighten pump and motor hold-down bolts 

before connecting the piping to pump.

3. SUCTION PIPING:

3.1.

 Low static suction lift and short, direct, suction 

piping is desired. For suction lift over 10 feet (3m)  

and liquid temperatures over 120ºF (50ºC), consult 

pump performance curve for Net Positive Suction 

Head Required.

3.2.

 Suction pipe must be at least as large as the 

suction connection of the pump. Smaller size will 

degrade performance.

3.3.

 If larger pipe is required, an eccentric pipe re-

ducer (with straight side up) must be installed at 

the pump.

3.4.

 Installation with pump below source of supply

3.4.1.

 Install full flow isolation valve in piping for 

inspection and maintenance.

Do not use suction isolation valve to 

throttle pump.

3.5.

 Installation with pump above source of supply

3.5.1.

 Avoid air pockets. No part of piping should 

be higher than pump suction connection. 

Slope piping upward from liquid source.

3.5.2.

 All joints must be airtight.

3.5.3.

 Foot valve to be used only if necessary for 

priming, or to hold prime on intermittent 

service.

3.5.4.

 Suction strainer open area must be at least 

triple the pipe area.

3.6.

 Size of inlet from liquid source, and minimum sub-

mergence over inlet, must be sufficient to prevent 

air entering pump through vortexing. See Figures 

2-5.

3.7.

 Use 3-4 wraps of Teflon tape to seal threaded 

 

connections.

16
15

14
13

12

11

10

9

8
7

6

5

4

3

2

1

H

1   2  3  4  5  6  7  8  9 10 11 12 13 14 15 16

V

Min.

 Submer

gence 

in 

feet

V = Velocity in feet per second

  =GPM x 0.321    GPM x 0.4085

Area                  D

2

1.5D

min.

3.0D

min.

D

D

H min.

D

 min.

2

---------

---------

D

H min.

D

H min.

---------

---------

Figure 2

Figure 4

Figure 5

Figure 3

Finished grouting

(1/4")

Grout hole

Base

Leveling wedges or shims—left in place

Top of foundation—

clean and wet down

Sleeve

Washer

Lug

(1/2 to 3/4")

Allowance

for leveling

Wood

frame

Grout

Figure 1

CAUTION

CAUTION

CAUTION

Содержание NPE

Страница 1: ...Model NPE NPE F INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS INSTRUCTION MANUAL IM013R11...

Страница 2: ...Operation 5 Maintenance 5 Disassembly 5 Reassembly 6 Troubleshooting Chart 6 NPE Standard Repair Parts List 7 Mechanical Seal Application Chart 7 Limited Warranty 8 Declaration of Conformity 24 Pump M...

Страница 3: ...are fully enclosed non trimable to intermediate diameters Casings are fitted with a diffuser for efficiency and for negligible radial shaft loading Close coupled units have NEMA 48J or 56J motors wit...

Страница 4: ...ed solid Allow grout to harden 48 hours before fully tight ening foundation bolts 2 3 5 Tighten pump and motor hold down bolts before connecting the piping to pump 3 SUCTION PIPING 3 1 Low static suct...

Страница 5: ...1 Before starting pump must be primed free of air and suction pipe full of liquid and discharge valve partially open Pumped liquid provides lubrication If pump is run dry rotating parts will seize an...

Страница 6: ...age may result Replacement of complete seal assembly whenever seal has been removed is good standard practice It is permissible to use a light lubricant such as glycerin to facilitate assembly Do not...

Страница 7: ...cknut AISI 316 S S 347 Guidevane AISI 316L S S Viton standard 349 Seal Ring guidevane EPR BUNA 370 Socket head screw casing AISI 410 S S 371 Bolts motor Steel plated 383 Mechanical seal 408 Drain and...

Страница 8: ...lacement directions shall terminate Seller s obligations under this Warranty and render the Warranty void Any parts repaired or replaced under the Warranty are warranted only for the balance of the wa...

Страница 9: ...Modelo NPE NPE F INSTRUCCIONES DE INSTALACI N FUNCIONAMIENTO Y MANTENIMIENTO MANUAL DE INSTRUCCI N IM013R11...

Страница 10: ...aje 13 Reensamble 14 Cuadro de Identificaci n de Problemas 14 Lista de repuestos est ndar NPE 15 Tabla de Aplicaci n del Sello Mec nico 15 Garant a Limitada 16 Declaraci n de Conformidad 24 N mero de...

Страница 11: ...n totalmente cerrados y no se pueden recortar a di matros intermedios Las carcasas est n equipadas con un difusor para eficiencia y que las cargas radiales sean negligibles en el eje Las unidades comp...

Страница 12: ...enrellenas Dejequelalechadafrag epor48horasantesde apretartotalmentelospernosdelacimentaci n 2 3 5 Apriete los pernos de sujeci n de la bomba y del motor antes de conectar la tuber a a la bomba 3 TUBE...

Страница 13: ...nar la bomba en seco las partes que giran se agarrotar n y se da ar el sello mec nico No haga funcionar con caudal muy bajo o cerca de cero La energ a impartida al l quido se convierte en calor y el l...

Страница 14: ...un lubricante ligero tal como glicerina para facilitar el montaje No contamine las caras del sello mec nico con lubricante 10 5 2 Inspeccione el anillo en O 513 de la car casa y c mbielo si est da ado...

Страница 15: ...casa AISI 316 S S Viton est ndar 412B Anillo en O tap n de drenaje EPR BUNA Viton est ndar 513 Anillo en O carcasa EPR BUNA NOTA COMPONENTES OPCIONALES DEL SELLO A RAS NOTA Las unidades de acoplamient...

Страница 16: ...i n o reemplazo del Vendedor rescindir las obligaciones del Vendedor en virtud de esta Garant a y anular esta Garant a Toda pieza reparada o reemplazada en virtud de la Garant a es garantizada solo po...

Страница 17: ...Mod lesNPEetNPE F DIRECTIVES D INSTALLATION D UTILISATION ET D ENTRETIEN MANUEL D UTILISATION IM013R11...

Страница 18: ...Utilisation 21 Entretien 21 D montage 21 Remontage 22 Diagnostic des Anomalies 22 Liste de Pi ces 23 Table des Garnitures Joints M caniques 23 Garantie Limit e 23 D claration de Conformit 24 Informat...

Страница 19: ...e un diam tre moindre par usinage Le corps de pompe est muni d un diffuseur pour en am liorer le rendement et diminuer la charge radiale de l arbre Les NPE sont mont es sur des moteurs NEMA 48J ou 56J...

Страница 20: ...pieds h 101112131415 16 v v vitesseenpiedsparseconde galUS minx0 321 sectiondepassage galUS minx0 4085 d2 Figure 1 Figure 2 Figure 3 Figure 4 2 3 4 Serrerlesboulonsd ancrage lamainetconstruire uncoffr...

Страница 21: ...et la garniture m ca nique se d t riorerait Ne pas faire marcher la pompe quand le d bit est nul ou presque car le liquide absorberait la chaleur produite par frottement et pourrait se changer rapidem...

Страница 22: ...garniture dont on ne doit pas con taminer la surface avec le lubrifiant 10 5 2 Inspecter le joint torique 513 du corps de pompe et le remplacer s il est endommag On peut employer du p trolatum vaseli...

Страница 23: ...ationduproduit la Garantie Sauf mentioncontrairedansleslois levendeur sonchoixetsansfraispourl acheteur r pareraouremplaceratoutproduitd fectueuxenvertudelagarantiepourautantque l acheteurdonneunavis...

Страница 24: ...dise ado para ser incor porado a la maquinaria cubierta por esta directiva pero no debe ponerse en funcionamiento hasta que se declare que la maquinaria en la que ser incorporado cumple con las dispos...

Отзывы: