Parameter number
Parameter name
Unit of measurement
Description
P03
Regulation Restart Value
[0-100]
G
%
It defines the start value
after the stop of the pump,
as a percentage of the P01
value. If the required value
is met and there is no
further consumption, then
the pump stops. The pump
starts again when the
pressure drops below P03.
P03 is valid when:
• Different from 100%
(100%=off)
• The control mode is
HCS, MSE or MSY.
Default: 100%.
P04
Auto-start [OFF-ON]
G
If P04 = ON, then the
pump starts automatically
following a power supply
disconnection.
If the pump is switched on
after setting P04 = OFF (see
Par. 6.5.1), it is stopped so
that the motor is not in
operation, and STP flashes
(STP
→
STP).
Default: ON.
P05
Operating time months
Total months of connection
to the electric mains, to add
to P06.
P06
Operating time hours
h
Total hours of connection to
the electric mains, to add to
P05.
P07
Motor Time Months
This parameter shows the
total operating time
months, to be added to
P08.
P08
Motor time hours
h
This parameter shows the
total operating time hours,
to be added to P07.
6 System Setup and Operation
Smart Pump Range INSTRUCTION MANUAL
31