![Xylem GOULDS 2GFK2412H Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/xylem/goulds-2gfk2412h/goulds-2gfk2412h_installation-operation-and-maintenance-manual_4127825009.webp)
DANGER: Explosion/Fire Hazard
Special rules apply to installations in explosive or flammable
atmospheres. Do not install the product or any auxiliary
equipment in an explosive zone unless it is rated explosion-
proof or intrinsically-safe. If the product is rated explosion-
proof or intrinsically-safe, then see the specific explosion-
proof information in the safety chapter before taking any fur-
ther actions.
NOTICE:
Do NOT use the unit in highly corrosive liquids.
Spare parts
• Modifications to the unit or installation should only be carried out
after consulting with Xylem.
• Original spare parts and accessories that are authorized by Xylem
are essential for compliance. The use of other parts can invalidate
any claims for warranty or compensation. For more information con-
tact your Xylem representative.
Model variants
L
Low head
M
Medium head
H
High head
S
Super high head
Parts
1
2
3
4
5
6
7
9
8
WS007964A
Po-
si-
tion
Denomi-
nation
Description
1
Shaft
Stainless steel with an integrated rotor
2
Stator
housing
Cooled by ambient liquid
3
Motor
For information about the motor, see
on page 19.
4
Mechani-
cal seal
Inner seal: carbon/aluminium oxide CSB/Al
2
O
3
Outer seal: corrosion-resistant cemented carbide/
aluminium oxide WCCR/Al
2
O
3
Po-
si-
tion
Denomi-
nation
Description
5
Oil hous-
ing
Includes coolant that lubricates and cools the seals;
acts as a buffer between the pumped fluid and the
electric motor
6
Impeller
Vortex
Non-clog
7
Main
bearing
Single-row ball bearing
8
Thermal
contact
The pump is equipped with thermal contacts, see
9
Support
bearing
Single-row ball bearing
3.3 Monitoring Equipment
The following applies to the monitoring equipment of the pump:
• The stator incorporates thermal contacts that are connected in ser-
ies that activate the alarm at overtemperature.
• The thermal contacts open at 125°C (257°F).
• Ex-approved pumps must have thermal contacts that are connected
to the control panel.
• The sensors must be connected to either the SMR 311 monitoring
equipment or equivalent equipment.
• The monitoring equipment must be of a design that makes auto-
matic restart impossible.
• Information in the junction box shows if the pump is equipped with
optional sensors
Optional sensors
LD LD is a miniature float switch for detection of liquid in the stator
housing. Due to its design, it is best suited for pumps in a vertical
position. The LD sensor is installed in the bottom of the stator
housing.
3.4 The data plate
The data plate is a metal label that is located on the main body of the
products. The data plate lists key product specifications. Specially ap-
proved products also have an approval plate.
WS006257C
24
23
25
8
7
6
5
4
13
12
14
17 18
19
16
15
9
10
11
22
21
20
2
3
1
1. Curve code or Propeller code
2. Serial number
3. Product number
4. Country of origin
5. Additional information
6. Phase; type of current; frequency
7. Rated voltage
8. Thermal protection
9. Thermal class
10.Rated shaft power
11.International standard
12.Degree of protection
13.Rated current
14.Rated speed
15.Maximum submergence
16.Direction of rotation: L=left, R=right
17.Duty class