Cause

Remedy

The density of the

pumped fluid is too

high.

Make sure that the maximum density is

1100 kg/m

3

 (9.2 lb/US gal)

• Change the impeller, or

• Change to a more suitable pump

• Contact a sales or authorized service rep-

resentative.

There is a malfunction

in the overload pro-

tection.

Replace the overload protection.

If the problem persists, then contact a sales or authorized service rep-

resentative.
Always state the serial number of the product, see 

Product Description

on page 5.

7.6  The pump delivers too little or no water

DANGER: Crush Hazard

Moving parts can entangle or crush. Always disconnect and

lock out power before servicing to prevent unexpected start-

up. Failure to do so could result in death or serious injury.

 

 

NOTICE:

Do NOT override the motor protection repeatedly if it has tripped. Do-

ing so may result in equipment damage.

Cause

Remedy

The impeller rotates in

the wrong direction.

• If it is a 3-phase pump, then transpose two

phase leads.

• If it is a 1-phase pump, then do the follow-

ing:
Contact a sales or authorized service rep-

resentative.

One or more of the

valves are set in the

wrong positions.

• Reset the valves that are set in the wrong

position.

• Replace the valves, if necessary.

• Check that all valves are correctly installed

according to media flow.

• Check that all valves open correctly.

The impeller is difficult

to rotate by hand.

• Clean the impeller.

• Clean out the sump.

• Check that the impeller is properly trim-

med.

The pipes are ob-

structed.

To ensure a free flow, clean out the pipes.

The pipes and joints

leak.

Find the leaks and seal them.

There are signs of

wear on the impeller,

pump, and casing.

Replace the worn parts.

The liquid level is too

low.

• Check that the level sensor is set correctly.

• Depending on the installation type, add a

means for priming the pump, such as a

foot valve.

If the problem persists, then contact a sales or authorized service rep-

resentative.
Always state the serial number of the product, see 

Product Description

on page 5.

8  Technical Reference

8.1  Motor data

Feature

Description

Motor type

Squirrel-cage induction motor

Frequency

50 Hz or 60 Hz

Supply

1-phase or 3-phase

Starting method

Direct on-line

Maximum starts per hour

15 evenly-spaced starts per hour

Code compliance

IEC 60034-1

Voltage variation without over-

heating

±10%, if it does not run continuously

at full load

Voltage imbalance tolerance

2%

Stator insulation class

F (155°C [311°F])

Motor encapsulation

Motor encapsulation is in accordance with IP68.

Application limits

Data

Description

Liquid temperature

Maximum 40°C (104°F)

Liquid density

1100 kg/m³ (9.2 lb per US gal) maximum

pH of the pumped me-

dia (liquid)

5.5–14 for cast iron pumps

Depth of immersion

Maximum 20 m (65 ft)

Other

For the specific weight, current, voltage, pow-

er ratings, and speed of the pump, see the

data plate of the pump.

8  Technical Reference

1310 Installation, Operation, and Maintenance Manual

19

Содержание GOULDS 2GFK2412H

Страница 1: ...Installation Operation and Maintenance Manual 90002801_3 0 1310...

Страница 2: ......

Страница 3: ...2GFK3212G 2GFK3213G 2GFK3214G 2GFK3215G 2GFK3812A 2GFK3813A 2GFK3814A 2GFK3815A 3GFK3812T 3GFK3813T 3GFK3814T 2GFV3212K 2GFV3213K 2GFV3214K 2GFV3215K 2GFV3812J 2GFV3813J 2GFV3814J 2GFV3815J Pump model...

Страница 4: ...8 4 2 Make the electrical connections 9 4 2 1 General precautions 9 4 2 2 Grounding earthing 9 4 2 3 Prepare the SUBCAB cables 9 4 2 4 Connect the motor cable to the pump 10 4 2 5 Connect the motor c...

Страница 5: ...8 Technical Reference 19 8 1 Motor data 19 Table of Contents 2 1310 Installation Operation and Maintenance Manual...

Страница 6: ...nearby equipment Qualified personnel This product must be installed operated and maintained by qualified personnel only Protective equipment and safety devices Use personal protective equipment as ne...

Страница 7: ...tention Chemicals or haz ardous fluids on skin 1 Remove contaminated clothing 2 Wash the skin with soap and water for at least 1 minute 3 Seek medical attention if necessary 1 6 Protecting the environ...

Страница 8: ...e pumped or mixed NOTICE Never use a naked flame to thaw the unit Unit in as delivered condition If the unit is still in the condition in which it left the factory all packing materials are undisturbe...

Страница 9: ...al contact The pump is equipped with thermal contacts see Monitoring Equipment on page 6 9 Support bearing Single row ball bearing 3 3 Monitoring Equipment The following applies to the monitoring equi...

Страница 10: ...ated explosion proof or intrinsically safe If the product is rated explosion proof or intrinsically safe then see the specific explosion proof information in the safety chapter before taking any fur t...

Страница 11: ...nt lifting device to the pump and to the ac cess frame For example you can use a stainless steel lifting chain with shackles b Fasten the cable to the cable holder Make sure that the cable cannot be s...

Страница 12: ...les These are the requirements to follow when you install cables The cables must be in good condition not have any sharp bends and not be pinched The cables must not be damaged and must not have inden...

Страница 13: ...e required power supply 5 Connect the mains leads L1 L2 L3 and ground earth according to applicable cable chart The ground earth lead must be 50 mm 2 0 in longer than the phase conductors in the junct...

Страница 14: ...ors and marking of main leads COLOR STANDARD STATOR LEADS BN Brown U1 U5 RD BK Black U2 U6 GN WH White V1 V5 BN OG Orange V2 V6 BU GN Green W1 W5 YE GN YE Green Yellow W2 W6 BK RD Red T1 T2 WH YE GY G...

Страница 15: ...U1 Z1 T1 T2 BK BN RD YE GC 1 BN RD 2 BK BK 3 GY WH 4 T1 OG 5 T2 BU 6 WH GN YE YE Starter 1 PHASE 12 Leads 1 U1 V1 W1 U2 V2 W2 U5 V5 W5 U6 V6 W6 U1 V1 U6 U2 W2 V6 V5 W1 W5 U5 V2 W6 U1 V1 W1 W2 U2 V2 GC...

Страница 16: ...essure level may exceed 70 dB A at certain operating points on the performance curve Make sure that you understand the noise level requirements in the environment where the product is installed Failur...

Страница 17: ...2 If it is necessary to separate the drive unit from the hydraulic unit then do the following a Carefully open the coolant plugs to relieve any built up pressure inside the cooling jacket CAUTION Com...

Страница 18: ...crews 2 Check the condition of the lifting handle and the chain 3 If necessary replace O rings 1 Replace the coolant plug O rings 2 Grease the O rings Service item Action Personnel safety de vices Che...

Страница 19: ...ad of the conical sleeve with a thin layer of grease The proper lubrication is grease for bearings for example Exxon Mobil Unirex N3 Mobil Mobilith SHC 220 or equivalent NOTICE Surplus grease can caus...

Страница 20: ...arance A between the impeller and the pump housing A 0 2 0 8 mm 0 008 0 032 in 10 Check that the impeller can rotate freely WARNING Crush Hazard Beware of the pinch point hazard between the rotating i...

Страница 21: ...distance between the start and stop levels is sufficient The non return valve s work s properly The length of the discharge pipe between the pump and the first non return valve is sufficiently short T...

Страница 22: ...otate by hand Clean the impeller Clean out the sump Check that the impeller is properly trim med The pipes are ob structed To ensure a free flow clean out the pipes The pipes and joints leak Find the...

Страница 23: ......

Страница 24: ...ced analytics solutions for water electric and gas utilities In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading pr...

Отзывы: