Special symbols

Some hazard categories have specific symbols, as shown in the following table.

Electrical hazard

Magnetic fields hazard

Electrical Hazard:

 

CAUTION:

 

1.3  User safety

All regulations, codes, and health and safety directives must be observed.

The site

• Observe lockout/tagout procedures before starting work on the product, such as

transportation, installation, maintenance, or service.

• Pay attention to the risks presented by gas and vapors in the work area.
• Always be aware of the area surrounding the equipment, and any hazards posed by

the site or nearby equipment.

Qualified personnel

This product must be installed, operated, and maintained by qualified personnel only.

Protective equipment and safety devices

• Use personal protective equipment as needed. Examples of personal protective

equipment include, but are not limited to, hard hats, safety goggles, protective gloves
and shoes, and breathing equipment.

• Make sure that all safety features on the product are functioning and in use at all times

when the unit is being operated.

1.4  Special hazards

Working in temporary installations

Certain industries, such as mining or construction, have a dynamic nature and require
temporary installation of equipment. Due to the rugged nature of these applications,
normal use of electrical equipment causes wear and tear that can result in insulation
breaks, short-circuits, and exposed wires. To maximize safety when using the unit in
rugged applications, the following conditions must be met:

• If electrical cables must be located such that they are at risk of being run over by heavy

equipment, then provide mechanical protection to prevent physical damage to the
cables.

• Visually inspect electrical equipment before use. Remove from service any equipment

with exposed wires or visible damage.

• Use ground-fault circuit interrupters on all receptacles, or have an assured equipment

grounding conductor program.

Biological hazards

The product is designed for use in liquids that can be hazardous to your health. Observe
these rules when you work with the product:

• Make sure that all personnel who may come into contact with biological hazards are

vaccinated against diseases to which they may be exposed.

• Observe strict personal cleanliness.

WARNING: Biological Hazard

Infection risk. Rinse the unit thoroughly with clean water before working on it.

1  Introduction and Safety

4

2008 Ready 8, 8S Installation, Operation, and Maintenance

Содержание Flygt 2008 Ready 8

Страница 1: ...Installation Operation and Maintenance 898397_4 0 2008 Ready 8 8S...

Страница 2: ......

Страница 3: ...8 3 4 The data plate 9 3 5 Product denomination 10 4 Installation 11 4 1 Install the pump 11 4 1 1 Install with S installation 12 4 2 Make the electrical connections 13 4 2 1 Connect the motor cable...

Страница 4: ...sequence 33 7 4 The pump runs but the motor protection trips 33 7 5 The pump delivers too little or no water 34 8 Technical Reference 36 8 1 Application limits 36 8 2 Motor data 36 8 3 Specific motor...

Страница 5: ...nts and information in the original manufacturer s manuals for any other equipment furnished separately for use in this system 1 2 Safety terminology and symbols About safety messages It is extremely...

Страница 6: ...such as mining or construction have a dynamic nature and require temporary installation of equipment Due to the rugged nature of these applications normal use of electrical equipment causes wear and...

Страница 7: ...disposal Observe the local regulations and codes regarding Reporting of emissions to the appropriate authorities Sorting recycling and disposal of solid or liquid waste Clean up of spills Exceptional...

Страница 8: ...tive if there is any issue 2 2 Transportation guidelines Precautions DANGER Crush Hazard Moving parts can entangle or crush Always disconnect and lock out power before servicing to prevent unexpected...

Страница 9: ...e liquid into a surrounding temperature below freezing Follow these guidelines to avoid freezing damage 1 Empty all pumped liquid if applicable 2 Check all liquids used for lubrication or cooling both...

Страница 10: ...ion about pH see Technical Reference on page 36 Particle size Version code 281 The pump can handle liquid containing particles that correspond to the pump housing inlet The diameter of the pump housin...

Страница 11: ...on to eliminate the level regulator function Illustration 1 2 WS006210B 1 On 2 Off Figure 1 The functionality of the level regulator 3 4 The data plate Introduction The data plate is located on the ma...

Страница 12: ...git The different types of codes are marked up with a b and c Code parameters are marked up with numbers Codes and parameters XXYYYY YYY YYY YYYY 1 2 3 4 5 6 7 a b c WS006265B Type of Callout Number I...

Страница 13: ...ion proof or intrinsically safe If the product is EN ATEX MSHA or FM approved then see the specific EX information in the Safety chapter before taking any further actions WARNING Explosion Fire Hazard...

Страница 14: ...able and intended to operate either completely or partially submerged in the pumped liquid The pump is equipped with a connection for hose or pipe These requirements and instructions only apply when t...

Страница 15: ...ake sure that electrical connections have been correctly made WARNING Crush Hazard Risk of automatic restart CAUTION Electrical Hazard Prevent cables from becoming sharply bent or damaged NOTICE Leaka...

Страница 16: ...r SUBCAB cables the twisted pair copper foil must be trimmed All unused conductors must be insulated Grounding earthing Grounding earthing must be done in compliance with all local codes and regulatio...

Страница 17: ...to ground earth 4 Firmly tighten the cable entry into its bottom most position The seal sleeve and the washers must conform to the outside diameter of the cables DANGER Explosion Fire Hazard Special r...

Страница 18: ...r 6 Diode 18 Contactor start relay or thermal relay 7 Motor cable 19 Thermal detector in stator 8 Screen 20 Thermal detector in main bearing 9 Pump 21 Jumper 10 Crimp connection 22 Terminal board term...

Страница 19: ...Make sure nobody is close to the unit when it is started Check the direction of rotation each time the cable has been re connected and after phase or total supply failure 1 Start the motor 2 Stop the...

Страница 20: ...not evaluated this unit for use in swimming pools If used in connection with swimming pools then special safety regulations apply Noise level NOTICE The sound power level of the product is lower than...

Страница 21: ...rush Hazard Never put your hand into the pump housing 4 Check that the monitoring equipment if any works 5 Check that the impeller rotation is correct 6 Start the pump 5 3 Clean the pump The pump must...

Страница 22: ...components have been thoroughly cleaned Make sure that the work area is well ventilated before you open any vent or drain valves remove any plugs or disassemble the unit Do not open any vent or drain...

Страница 23: ...ads For hexagon socket head screws with countersunk head maximum torque for all property classes must be 80 of the values for property class 8 8 above 6 2 Service Regular service of the pump ensures m...

Страница 24: ...Air inside the chamber may cause parts or liquid to be propelled with force Be careful when opening Hold a rag over the plug to prevent liquid from spraying out 3 Turn the pump so that the oil hole f...

Страница 25: ...rts can have sharp edges Wear protective clothing 1 Remove the strainer WS002031A 3x 2 Remove the diffuser WS002032A 3 Remove the impeller a Remove the impeller screw and washer b Pull off the impelle...

Страница 26: ...Hazard Worn parts can have sharp edges Wear protective clothing 1 Remove the pump housing unit WS002030B 3x 2 Remove the impeller a Remove the impeller screw and washer b Pull off the impeller 6 Main...

Страница 27: ...d This is to prevent the shaft from rotating with the impeller screw 3 Fasten the impeller a Place the washer on the impeller screw b Mount the impeller Make sure that the impeller hub disk center is...

Страница 28: ...ft must be clean and free from burrs 2 Check that the impeller screw is clean and easy to screw into the shaft end This is to prevent the shaft from rotating with the impeller screw 3 Fasten the impel...

Страница 29: ...ing torque 9 3 Nm 6 9 ft lbs d Check that the impeller can rotate freely 4 Mount the pump housing unit WS002030B 3x 5 Tighten the screw s Tightening torque 9 3 Nm 6 9 ft lbs 6 Maintenance 2008 Ready 8...

Страница 30: ...cable entry WS003053A 2 Remove the pump top 3x WS003054A 3 Disconnect the motor cable from the terminals a Disconnect the power lead s b Disconnect the ground earth lead s 4 Remove the motor cable 6...

Страница 31: ...the terminals See Make the electrical connections on page 13 If the cable is damaged then cut off the damaged part and install new terminals a Connect the ground earth lead s b Connect the power lead...

Страница 32: ...3x WS003056A 4 Tighten the cable entry Make sure that it bottoms out WS003053A 6 Maintenance 30 2008 Ready 8 8S Installation Operation and Maintenance...

Страница 33: ...wer before servicing to prevent unexpected startup Failure to do so could result in death or serious injury E q u ip m e n t lo c k e d o u t b y N a m e D A N G E R NOTICE Do NOT override the motor p...

Страница 34: ...r before servicing to prevent unexpected startup Failure to do so could result in death or serious injury E q u ip m e n t lo c k e d o u t b y N a m e D A N G E R Cause Remedy The pump is unable to e...

Страница 35: ...page 8 7 4 The pump runs but the motor protection trips DANGER Crush Hazard Moving parts can entangle or crush Always disconnect and lock out power before servicing to prevent unexpected startup Failu...

Страница 36: ...t see Product Description on page 8 7 5 The pump delivers too little or no water DANGER Crush Hazard Moving parts can entangle or crush Always disconnect and lock out power before servicing to prevent...

Страница 37: ...r is set correctly Depending on the installation type add a means for priming the pump such as a foot valve If the problem persists then contact a sales or authorized service representative Always sta...

Страница 38: ...Motor type Squirrel cage induction motor Frequency 50 Hz or 60 Hz Supply 1 phase Maximum starts per hour 15 evenly spaced starts per hour Code compliance IEC 60034 1 Voltage variation without overhea...

Страница 39: ...0 Hz Motor type 2 800 rpm 900 W 1 2 hp Voltage V Rated current A Starting current A 115 11 43 230 5 2 19 240 5 20 1 phase 60 Hz Motor type 3 330 rpm 820 W 1 1 hp Voltage V Rated current A Starting cur...

Страница 40: ...5 Dimensions and weights Ready 8 WS001176A A B A 438 mm 17 2 in B 184 mm 7 2 in Weight without motor cable 14 5 kg 32 lb 8 Technical Reference 38 2008 Ready 8 8S Installation Operation and Maintenanc...

Страница 41: ...mm 7 8 in C 263 mm 10 4 in Weight without motor cable 17 kg 37 lb 8 6 Performance curves Test standard Pumps are tested in accordance with ISO 9906 2012 HI 11 6 2012 8 Technical Reference 2008 Ready...

Страница 42: ...Ready 4 Ready 4L WS006426B Ready 4L Ready 4 Figure 4 50 Hz 0 1 2 3 4 5 6 0 20 40 60 80 100 0 2 4 6 8 10 12 14 0 10 20 30 40 50 0 0 0 2 0 4 0 6 0 8 1 0 0 0 0 5 1 0 1 5 Ready 8S Ready 8S Ready 8 Ready...

Страница 43: ......

Страница 44: ...k technologies and advanced data analytics for water gas and electric utilities to its portfolio of solutions In more than 150 countries we have strong long standing relationships with customers who k...

Отзывы: