Voltage (V)
Rated current (A)
Starting current (A)
115
9.8
40
230
4.8
17
8.4 Specific motor data: Ready 8S
1-phase, 50 Hz
Motor type:
• 2,800 rpm
• 900 W (1.2 hp)
Voltage (V)
Rated current (A)
Starting current (A)
115
11
43
230
5.2
19
240
5
20
1-phase, 60 Hz
Motor type:
• 3,330 rpm
• 820 W (1.1 hp)
Voltage (V)
Rated current (A)
Starting current (A)
115
9.8
40
230
4.8
17