1: SAFETY INSTRUCTIONS                  

TO AVOID SERIOUS OR FATAL PERSONAL INJURY  

OR MAJOR PROPERTY DAMAGE, READ AND 

FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL 

AND ON EQUIPMENT.
THIS MANUAL IS INTENDED TO ASSIST IN THE 

INSTALLATION AND OPERATION OF THIS UNIT  

AND MUST BE KEPT WITH THE UNIT.

This is a SAFETY ALERT SYMBOL.  

When you see this symbol on the pump, 

the controller or in the manual, look for 

one of the following signal words and 

be alert to the potential for personal 

injury or property damage.
Warns of hazards that WILL cause 

serious personal injury, death or major 

property damage.
Warns of hazards that CAN cause serious 

personal injury, death or major property 

damage.
Warns of hazards that CAN cause   

personal injury or property damage.

NOTICE:  

INDICATES SPECIAL    

 

 

INSTRUCTIONS WHICH ARE    

 

VERY IMPORTANT AND MUST BE  

 FOLLOWED.
THOROUGHLY REVIEW ALL INSTRUCTIONS  

AND WARNINGS PRIOR TO PERFORMING ANY 

WORK ON THIS CONTROLLER.
MAINTAIN ALL SAFETY DECALS.

DANGER

WARNING

CAUTION

This controller is not designed for use 

around swimming pools, open bodies of 

water, hazardous liquids, or where flammable gases exist.

Do not use GFCI input power. This will 

cause nuisance faults.
Disconnect and lockout electrical power 

before installing or servicing any  

electrical equipment.

ELECTROCUTION HAZARD. 

CONTROLLER INPUT GROUND 

TERMINAL (GND) AND ALL EXPOSED METAL 

PIPING, INCLUDING PRESSURE TRANSDUCER 

CASE, MUST BE CONNECTED TO THE SERVICE 

ENTRANCE GROUND TERMINAL.

All electrical work must be performed 

by a qualified technician. Always follow 

the National Electrical Code (NEC), or the Canadian 

Electrical Code, as well as all local, state and provincial 

codes. Code questions should be directed to your local 

electrical inspector. Failure to follow electrical codes and 

OSHA safety standards may result in personal injury or 

equipment damage. Failure to follow manufacturer’s 

installation instructions may result in electrical shock,  

fire hazard, personal injury or death, damaged 

equipment, unsatisfactory performance, and may void 

manufacturer’s warranty.

WARNING

WARNING

WARNING

WARNING

1: SAFETY INSTRUCTIONS

WARNING

NOTICE: Some installations pull a vacuum on the 

transducer when the system is drained. The new controller 

is designed to protect against up to 17" Hg. of vacuum 

on the transducer.  An optional Gauge Guard, order no. 

6K210, will protect the transducer from a vacuum and 

corrosive or dirty water.

Installation Quick Steps

  1. Mount the controller in a vertical position.
  2. Wire input power to unit.
  3. Wire motor drop cable to unit. All splices done with 

heat shrinks.

  4. Mount pressure transducer.
  5. Wire and ground pressure transducer.
  6. User Interface Board:
 

1. Set overload per motor SFA

 

2. Select maximum frequency (3Ø only)

 

3. Dry well – on high

 

4. Low pressure cut-off – on

 

5. Pump stop sensitivity - low

  7. Adjust tank pre-charge
  8. Power on and purge system of air.
  9. Adjust set point pressure.
10. Check rotation and performance.

Ratings

Refer to serial number label on enclosure.

Required Materials

• Pump Controller with Transducer and Transducer Wire
• Pump (water end)

  (see Speed Selector Switch for 60 Hz or 80 Hz Operation)
• Motor
• Pressure Relief Valve – piped to a drain for safety
• Pressure Gauge – for setting system pressure
• Heat Shrink Kit – one required for each underwater or 

underground splice (mandatory)

• Tank Tee or (2) ¼" NPT Female pipe fittings for pressure 

sensor and pressure gauge connections

• Pipe and fittings – as necessary per each system
• Disconnect Switch: 230 V, 2 pole, properly sized    

(see Controller, Breaker, Generator Sizing Table)

• Copper Wire: Minimum 75ºC rated wire, double 

jacketed is recommended but not mandatory  

 

(see Wire Sizing table)

• Tank: diaphragm style tank  

 

 

 

(see Tank Sizing Section and Chart)

2: TYPICAL INSTALLATION

Determine where the Controller, Pressure Tank and 

Transducer will be located before starting the installation.

Controller

The controller is rated NEMA 3R (Raintight) so it may be 

located outdoors. It must be mounted vertically. Locate 

the enclosure in a shaded area where the temperature 

stays within 14ºF to +122ºF (-10ºC to +50ºC). Since 

the controller is designed for outdoor mounting it may be 

located at the wellhead.

2: TYPICAL INSTALLATION

Содержание CentriPro Aquavar SOLO

Страница 1: ...AQUAVAR SOLO SUBMERSIBLE PUMP CONTROLLER INSTALLATION OPERATION AND TROUBLESHOOTING MANUAL INSTRUCTION MANUAL IM229R06...

Страница 2: ...tings Options 11 12 7 Troubleshooting Fault Codes 13 15 Limited Warranty 16 Table of Contents PLEASE USE THIS CONTROLLER INSTALLATION OPERATION AND TROUBLESHOOTING MANUAL IOM IN CONJUNCTION WITH THE P...

Страница 3: ...tisfactory performance and may void manufacturer s warranty WARNING WARNING WARNING WARNING 1 SAFETY INSTRUCTIONS WARNING NOTICE Some installations pull a vacuum on the transducer when the system is d...

Страница 4: ...ck valve between pump and tank for reliable turn off when flow stops TANK SIZING AND TANK PRESSURE SETTING Refer to Table 1 for recommended tank size On pre existing systems larger tanks may be used T...

Страница 5: ...ect The circuit board near the terminal block is labeled to show where to connect the motor wires For all motors the green wire from the motor must be attached to the terminal labeled GND For 2 wire 1...

Страница 6: ...to a Maximum of 50 C 122 F Ambient Temperature Output HP 14 12 10 8 6 4 3 2 1 1 0 2 0 3 0 4 0 250 300 350 400 500 690 1100 1748 2523 3978 6316 7884 9945 1 558 890 1413 2040 3216 5106 6375 8041 230V 1...

Страница 7: ...g value for pump motor Circuit Breaker or Dual Element Time Delay Fuse Size Amps protecting branch circuit supplying controller Minimum size of single phase 240 V genera tor required 230 Volt 200 Volt...

Страница 8: ...ng before applying power may damage the motor or wire and void the warranty Use Tables 3 and 4 to determine which controller and setting to use Note that some 200V motors require upsizing to the next...

Страница 9: ...0 PSI Transducer Not Connected Transducer Jumper Top Position Installer Must Move Float Switch Connected to Switch Input Checking for leaks Constant pressure systems utilizing small tanks run whenever...

Страница 10: ...tion resistance Condition of Motor and Leads Ohms Megohm Value Value A new motor without drop cable 20 000 000 20 0 or more A used motor which can be 10 000 000 10 0 reinstalled in the well or more Ne...

Страница 11: ...licable after a description there is a table showing which pushbutton s and DIP switch to use to make a particular setting The tables show which pushbutton s to hold down which DIP switch to flip and...

Страница 12: ...will also clear the restart time back to 1 minute Pushbutton DIP Switch Direction to Dry Well Restart Time to Hold to Flip Flip Down DIP Switch Increasing 1 10 20 30 60 min Both Top Left to Right Fix...

Страница 13: ...ler fault To clear the fault turn off power to the controller Red wait 1 minute turn on power to the controller If fault persists replace controller 2 Blinks Dry Well This fault can be caused by Water...

Страница 14: ...ation with megger Verify the error by turning power to controller off for 1 minute and then on Pump Motor must be checked if fault persists 5 Blinks Short Circuit This fault can be caused by Electrica...

Страница 15: ...nd replacements are available 8 Blinks Open Lead This fault can be caused by Disconnected or broken wire between the controller and motor Verify the error by turning power to controller off for 1 minu...

Страница 16: ...sement for loss caused by interruption of service c Reinstallation costs of replacement equipment For purposes of this warranty the following terms have these definitions 1 Distributor means any indiv...

Страница 17: ...AQUAVAR SOLO CONTROLADOR DE BOMBA SUMERGIBLE MANUAL DE INSTALACI N OPERACI N Y RESOLUCI N DE PROBLEMAS MANUAL DE LA INSTRUCCI N IM229R06...

Страница 18: ...ia de aislamiento y devanado 26 27 6 Ajustes Opciones avanzados 27 28 7 Resoluci n de problemas c digos de fallas 29 31 Garant a limitada 32 ndice Informaci n del propietario POR FAVOR USE ESTE MANUAL...

Страница 19: ...O FATALES O DA OS SIGNIFICATIVOSALAPROPIEDAD LEAYRESPETETODAS LAS INSTRUCCIONES DE SEGURIDAD EN ELMANUALYEN ELEQUIPO LAFINALIDAD DE ESTE MANUALESAYUDAR EN LA INSTALACI NYOPERACI N DE ESTAUNIDADYSE DE...

Страница 20: ...daciones Ubique el tanque y el transductor en donde no se puedan llegar a congelar Aseg rese de que la configuraci n de la presi n del sistema no exceda la presi n efectiva m xima del tanque Para un d...

Страница 21: ...C digo Nacional de Electricidad Art culo 250 El cable del transductor viene con un cable a tierra Verde y una abrazadera de conexi n a tierra para facilitar la tarea de conectar el transductor a tierr...

Страница 22: ...trolador motor 14 12 10 8 6 4 3 2 1 1 0 2 0 3 0 4 0 250 300 350 400 500 690 1100 1748 2523 3978 6316 7884 9945 1 558 890 1413 2040 3216 5106 6375 8041 1 445 709 1126 1625 2562 4068 5078 6406 8072 2 32...

Страница 23: ...dDeDetenci nDeBomba Frecuencia m xima Ca da de presi n Ca da de presi n Sensibilidad de Pozo Seco Sensibilidad de Pozo Seco Protecci n de Tuber a Rota Protecci n de Tuber a Rota ENCEN DIDO ENCEN DIDO...

Страница 24: ...n antes de que la bomba se reinicie se puede configurar en el est ndar de 5 PSI o en 20 PSI La configuraci n de 20 PSI provoca menos arranques en sistemas con p rdidas Se recomienda para sistemas de...

Страница 25: ...5 10 PSI por debajo de la presi n de salida de la v lvula de alivio de presi n PRV Esto apagar el sistema antes de que se abra la v lvula de alivio de presi n AJUSTE DE PRESI N SOLO SI SE DESEA UNA P...

Страница 26: ...tajo de la presi n baja Encendido cambie a apagado si la presi n cae 20 PSI o m s Ca da de presi n 5 PSI Transductor Conectado Puente de conexi n del transductor Posici n inferior configuraci n de f b...

Страница 27: ...os rojos cuando el pozo est seco primero aseg rese que el ajuste de sobrecarga del motor sea el correcto Luego realice la Calibraci n de energ a de pozo seco con el sistema en el flujo m ximo abra var...

Страница 28: ...Sensibilidad Alta utiliza 80 RESETEO MANUAL DE FALLA DE POZO SECO Al instalar y probar el sistema es conveniente tener una manera r pida de borrar una falla de Pozo Seco Si se presionan ambos botones...

Страница 29: ...a apague el espere 1 minuto vuelva a encenderlo Si la falla persiste reemplazar el controlador espere 1 minuto controlador vuelva a encenderlo Si la falla persiste reemplazar el controlador 2 Pozo sec...

Страница 30: ...nte con el megger Verifique el error apagando el suministro de energ a al controlador por 1 minuto y volvi ndolo a encender Si la falla persiste la bomba el motor deben ser revisados 5 Cortocircuito E...

Страница 31: ...rna del ventilador no est bloqueado o tapado Puede ser extra do para su limpieza y hay piezas de recambio disponibles 8 Conductor abierto Esta falla puede ser provocada por parpadeos Cable desconectad...

Страница 32: ...mplazo d Da os resultantes de cualquier tipo y e Reembolso de p rdidas causadas por la interrupci n del servicio A los fines de esta garant a los siguientes t rminos tienen estas definiciones 1 Distri...

Страница 33: ...AQUAVAR SOLO CONTR LEUR POUR POMPES SUBMERSIBLES MANUEL D INSTALLATION D UTILISATION ET DE D PANNAGE MANUEL D INSTRUCTION IM229R06...

Страница 34: ...e de contacteur fonctions 41 5 Essais de r sistance d isolement et de bobinage 42 6 R glages et choix volu s 42 7 D pannage et code des anomalies 45 Garantie limit e 48 Table des mati res UTILISER LE...

Страница 35: ...icant AVIS la vidange de certains syst mes peut causer une d pression dans le capteur Le nouveau contr leur prot ge celui ci contre les d pressions atteignant 57 56 kPa colonne de 17 po de mercure Le...

Страница 36: ...oir la table 1 pour les capacit s recommand es des r servoirs Des r servoirs plus gros sont permis dans les syst mes ant rieurs Table 1 Syst mes petits r servoirs D bit de la pompe Capacit totale mini...

Страница 37: ...fouissement ou l immersion ou les deux La figure 2 montre les bornes de connexion des fils d entr e et de moteur Les bornes de connexion du moteur sont indiqu es sur le circuit imprim voisin du bornie...

Страница 38: ...exposition une temp rature ambiante maximale de 50 C 122 F contr leur hp 14 12 10 8 6 4 3 2 1 0 00 000 0000 250 300 350 400 500 690 1100 1748 2523 3978 6316 7884 9945 1 558 890 1413 2040 3216 5106 637...

Страница 39: ...n activ e ON ou d sactiv e OFF 6 Chute de pression 5 ou 20 lbf po psi 7 R glage de la pression 8 Augmenter 9 R duire 10 S lecteur limiteur de surcharge du moteur 11 Voyant d tat 12 R glage de la surch...

Страница 40: ...gl e avant la mise sous tension peut ab mer le moteur ou le c blage et annuler la garantie Dans les tables 3 et 4 choisir le contr leur et l AFS appropri s Certains moteurs de 200 V requi rent le cont...

Страница 41: ...ENTR E DE CONTACTEUR connexion pour commande ou contacteur ext rieurs d marrant et arr tant le moteur ainsi que pour pressostat contacteur flotteur contacteur non aliment en courant etc pour le d bit...

Страница 42: ...ms est normale le bobinage du moteur n est pas la terre et l isolant du c ble n est pas ab m 2 Si la valeur en ohms est inf rieure la normale le bobinage est la terre ou bien l isolant du c ble est ab...

Страница 43: ...on n appuiera pas sur un bouton On peut modifier les r glages autant qu on le veut S assurer de replacer les commutateurs dans la position requise apr s le r glage R INITIALISATION DES R GLAGES PAR D...

Страница 44: ...RESSION DANS LA D TECTION D COULEMENT Le contr leur se sert de la variation de pression pour d tecter la fin de l coulement La variation par d faut est de 2 lbf po mais on peut choisir 1 lbf po et 3 l...

Страница 45: ...r leur Une anomalie s est produite dans le contr leur Pour effacer l anomalie couper le courant du contr leur attendre 1 min puis r tablir le courant Si l anomalie persiste remplacer le contr leur 2 c...

Страница 46: ...ompe et le moteur 5 cligno Anomalie Court circuit Cette anomalie peut tre caus e par tements une panne de moteur d origine lectrique la d faillance du c ble reliant le contr leur au moteur Couper le c...

Страница 47: ...il reliant le contr leur au moteur Couper le courant pendant 1 min puis le r tablir pour savoir si l anomalie persiste Si oui il faudra v rifier le moteur et le c blage le reliant au contr leur Couper...

Страница 48: ...ne couvre pas a les frais de main d uvre ni de transport ni les frais connexes encourus par le d taillant b les frais de r installation du mat riel r par c les frais de r installation du mat riel de r...

Отзывы: