5017T Flat Panel Industrial Touch Monitor Chapter 2 – Installation
6
Panel Installation
This monitor should be mounted and used where NEMA 4 and NEMA 12 type
enclosures are employed. When mounted properly, the monitor meets or exceeds the
sealing requirements set forth in the NEMA 4 and NEMA 12 specifications. The
monitor uses "U"-shaped clips and a special gasket to achieve the proper seal.
Make a cutout in one of the walls of your NEMA enclosure (see Figure 2-4 for cutout
dimensions). Enclosures made of heavier gauge metal work better in that they won't
deform or bend as easily when the monitor's sealing gasket is compressed.
Figure 2-4. 5017T Cutout Dimensions
The 5017T has 14 total mounting clips: 4 on the both the top and bottom of the
monitor, and 3 mounting clips on both of the sides. Hold the monitor in place while
you install the mounting clips (see Figure 2-5 for mounting clip locations). Tighten
the clips in a crisscross pattern. This will help to develop an even pressure on the
sealing gasket. Tighten the clips until the back of the monitor's front bezel begins to
contact the front of the NEMA enclosure (at least 7 in-lbs of torque).
Caution
Over-tightening the clips can cause damage to the monitor, which can result
in loss of seal integrity.