3700 Series Flat Panel Industrial PC
Chapter 4 – Maintenance
51
143311 (H)
3. Plug the IDE ribbon cable into the hard drive. The connector is keyed
4. Plug the DC power cable into the hard drive. The connector is keyed
5. Carefully insert the hard drive assembly back into the spring-loaded slot inside of the 3700
series computer. To do this, be sure that the cables do not lay underneath the hard drive. The
HDD ACCESS cover has two guide pins to ensure proper alignment on the upper left and
lower right corners. Slide the HDD ACCESS cover guide pins into the holes and gently apply
pressure to seat the hard drive into the assembly spring below. Tighten the two captive screws
that secure the ‘HDD ACCESS’ cover.
6. Install the rear chassis top cover (five #6 screws on back).
TO SETUP THE CMOS MEMORY:
1. Plug a QWERTY keyboard into the Keyboard port on the side of the 3700 series computer
2. Apply power to the 3700 series computer. The same ERROR and WARNING messages
should appear as before battery replacement. This is because the CMOS memory must be
setup:
ERROR
0271: Check Date and Time Settings
Warning
0251: System CMOS Checksum Bad – Default
Configuration Used
Press <F1> to Resume, <F2> to Setup
3. Press the QWERTY keyboard F2 function key to enter CMOS Memory SETUP
4. The SYSTEM TIME and SYSTEM DATE fields are located at the top of the MAIN tab
screen. Use the UP and DOWN arrow keys on the keyboard to move from field to field. Use
the TAB key to move between the [HH:MM:SS] and [MM/DD/YYYY] sub-fields to enter the
present time and date.
5. Press the QWERTY keyboard F10 function key to SAVE AND EXIT.
6. Lithium battery replacement is now complete. The computer should boot with no error or
warning messages.
Product Repair Program
Pro-face’s Product Repair & Customization Department (PR&C) restores
equipment to normal operating condition and implements engineering changes that
enhance operating specifications. Pro-face tests products returned to Pro-face with
the standard Pro-face test diagnostics.
Follow the steps below to prepare the unit for shipment:
1. Obtain a Return Merchandise Authorization (RMA) number for your unit by
calling your nearest Pro-face Repair Department or Xycom Automation, LLC at
734-429-4971.
2. Please have the following information:
•
Company name, shipping and billing address
•
Type of service desired: product repair or product exchange
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com