D. Activating the timer function:   

1.

 

While the blower (motor) is running, press and hold Power button for over 3 seconds to activate delay 
off timer. Power-off delay indicator will lit up and power-off delay digital timer will begin to 
countdown, when it reaches zero, the blower (motor) will shut down. 

 
E. To clear cleaning reminder: 

 

When blower (motor) starts to rotate, cumulative running time will be shown in 

Power-On 

Elapsed Digital Timer

. This timer icon flashes when 30 hours is up and reminds user to clean the 

aluminum filter.   

 

After cleaning the filter and when the motor is not in use, press and hold (+) 

Increase Value 

button over 3 seconds to reset the timer. Please note that turning off the system will not reset the 

Power-On Elapsed Digital Timer

.  

 
TROUBLE SHOOTING 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

 
 
 
 

1.  If the range hood or lights does not operate 
after installation: 
 
 
 
 
 
 
2.  The range hood vibrates when the blower is 
on:  
 
 
 
 
3.    The blower or fan seems weak:   
 
 
 
 
 
 
 
 
 
4.    The lights work but the blower is not spinning 
at all, is stuck or is rattling. 
 
 
 
 
5.    The hood is not venting out properly: 

 

 

Check if the range hood has been plugged in, make 
sure that all power has been turned back ON, the 
fuse is not blown and all electrical wiring is 
properly connected.   

 

Swap out light assembly to working ones to deter• 
mine whether it is caused by defective bulbs. See 

replacing the light bulbs 

on Page 17.

 

 

 

The range hood might not have been secured prop-
erly on to the ceiling or wall.

 

 

Check if the motor is secured in place.  If not, 
then tighten the motor in place.

 

 

Check if the blower wheel is a damaged.   

 

 

 

Check that the duct sized used is at least 6” or 3-
1/4 x 10”. Range hood WILL NOT function 
efficiently with insufficient duct size. For example: 
7” duct over 6” hole and loosely secured.   

 

Check if duct is clogged or if damper unit (half-cir-
cular flapper) is not installed correctly or opening 
properly. A tight mesh on a side wall cap unit 
might also cause restriction to the air flow.

 

 
 

 

The blower might be jammed or scraping the bot-
tom due to shipping damage. Please contact us im-
mediately.

 

 

The motor is defective, possibly seized - change 
the motor.

 

 

 

Make sure the distance between the stove top and 
the bottom of the hood is within 27” and 33” in 
distance. 

Due to different ceiling height configura-

tions, recommended height may not be applicable.

 

 

Reduce the number of elbows and length of duct 
work. Check if all joints are properly connected, 
sealed, and taped.   

 

Make sure the power is on high speed for heavy • 
cooking.

 

Содержание PX04-I

Страница 1: ...www XtremeAirUsa com Page 1 Island Mount Range Hood For residential use only READ AND SAVE THESE INSTRUCTIONS PRO X SERIES INSTALLATION GUIDE USER S MANUAL PX04 I Model ...

Страница 2: ...lowing text TABLE OF CONTENTS Important Safety Note 3 Parts supplied 4 Tools needed 5 Venting methods 5 Mount heights clearance 6 Venting requirements 6 Electrical requirements 7 Installation 8 10 Range hood operations 11 12 Troubleshooting 12 Use and care information 13 Maintenance 14 Specifications 15 Replacing light bulb 15 Warranty Customer Support 16 IMPORTANT SAFETY NOTICE ...

Страница 3: ...quently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages 9 When cutting or drilling into wall or ceiling be careful not to damage electrical wiring or other hidden utilities 10 All electrical wiring must be properly installed insulated and grounded 11 Before servicing or cleani...

Страница 4: ...www XtremeAirUsa com Page 4 PART SUPPLIED Note DO NOT remove the plastic covering on the chimneys this time as it protects chimneys from scratches during installation ...

Страница 5: ...www XtremeAirUsa com Page 5 TOOLS NEED FOR INSTALLATION VENTING METHODS ...

Страница 6: ...mended between stove top and the bottom of range hood It is recommended that the range hood be vented vertically through the roof through 6 or bigger vent work ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long reducer instead of a pancake reducer Reducing duct size will restrict airfl...

Страница 7: ...tallation Guide for electrical inspector s use DO NOT ground to a gas pipe Check with a qualified electrician if you are not sure that the range hood is properly grounded DO NOT have a fuse in the neutral or ground circuit The range hood must be connected with copper wire plug only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored o...

Страница 8: ...www XtremeAirUsa com Page 8 INSTALLATION ...

Страница 9: ...go 6 Mark the 4 ceiling mounting holes 1 Cut out a hole in the ceiling where the ducting will go 2 Place chimney bracket against ceiling and screw into place 3 Drop the ducting and electrical work through the ceiling NOTE Use threaded drywall anchors only when mounting the hood on sheet rock Mounting the hood on ceiling studs or lumbers is a must 1 Attach UPPER BRACKETS vertically outside the 4 co...

Страница 10: ...y drop outer chimney down until it perfectly sits on the hood body Note To avoid scratching the chimney extend the lower or outer chimney slowly and carefully to the hood body 1 Feed electrical and ducting work through chimneys 2 Place the base of the hood directly under the support brackets 3 Screw hood to the support brackets on all 4 corners as show 5A 4 Connecting the pipe 5B 1 Slide inner and...

Страница 11: ...n delay timer function is on A Adjusting the blower motor speed There are 4 speeds on your hood 1 Press 1 Power button once to turn on the system The Blower Power Indicator icon flashes showing that the blower motor is ready 2 Decrease Value button will decrease the speed of the blower motor from 4 to 1 strongest to quietest Increase Value button will increase the speed of the blower motor from 1 ...

Страница 12: ...has been turned back ON the fuse is not blown and all electrical wiring is properly connected Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs See replacing the light bulbs on Page 17 The range hood might not have been secured prop erly on to the ceiling or wall Check if the motor is secured in place If not then tighten the motor in place Check if the b...

Страница 13: ... risk of self combustion is higher when the oil has been used several times NEVER cook on open flames under the range hood Check deep fryers during use Superheated oil may be flammable Cleaning The saturation of greasy residue in the blower and filters may cause increased inflammability Keep unit clean and free of grease and residue build up at all times to prevent possible fires FILTERS MUST BE C...

Страница 14: ...ay adhere to the surface and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after exposure and wipe dry with a clean cloth Cleaning Aluminum Grease Filter Stainless Steel Filter less Grill IMPORTANT Drain oil from oil...

Страница 15: ...gal Squirrel Cage Filtration Type Stainless Steel Flat Filter Illumination LED light 2W Maximum Venting Size Top 6 inches Round Interference Protection Radio Frequency Interference Protected NOTE Specification subject to change without notice please contact your local reseller for details REPLACING THE LIGHT BULB 1 Make sure the range hood is unplugged or turn OFF breaker 2 Use the small flat crew...

Страница 16: ...f The Company The warranty does not include normal maintenance and service The Warranty does not cover the costs of removal installation In the event of a products replacement or return the unit must be returned transportation prepaid The repaired or new model will be returned at the company expense The warranty on your XtremeAir hood begins on the date of original purchase Please complete the Pro...

Отзывы: