background image

                                                 

www.XtremeAirUsa.com

 

                                                                  PAGE 

3

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
     
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

WARNING

 

-

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, 

OBSERVE THE FOLLOWING: 

 

ƒ

Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer 

 

PRODUCT: 

Do not remove permanently affixed labels, warnings, or plates from the product.    This may void the 

warranty. Do not try to alter the hood 
 

INSTALLATION

:

 

The installation in this manual is intended for qualified installers, service technicians or persons 

with similar qualified background.  Installation and electrical wiring must be done by qualified professionals and 
in accordance with all applicable codes and standards, including fire-rated construction.  When cutting or drilling 
into wall or ceiling; do not damage electrical wiring and other utilities.    Due to the size and weight of this range 
hood, two people installation is recommended.  Range hood may have very sharp edges; please wear protective 
gloves if it is necessary to remove any parts for installing, cleaning or servicing. 
 

VENTTING: 

For kitchen range or cook top ventilating use only.    DO NOT use to exhaust hazardous or explosive 

materials and vapors.  Ducted fans MUST always be vented to the outdoors.  DO NOT vent exhaust into spaces 
between walls, crawl spaces, ceiling, attics or garages.  Use only metal ductwork.  Old duct work should be 
cleaned or replaced if necessary to avoid the possibility of a grease fire.  Check all joints on duct work to insure 
proper connection and all joints should be properly taped. 

 
ELECTRICAL: 

All electrical wiring must be properly installed, insulated and grounded.  Before servicing or 

cleaning unit, turn power OFF and un-plugged   

 
OPERATION: 

Use high settings on cooking range only when necessary.  Keep all fan, baffle, spaces, filter, 

grease tunnel, oil container and grease-laden surfaces clean.  Grease should not be allowed to accumulate on fan, 
baffle, spaces, filter, grease tunnel and oil container.    Never allow the filters to become blocked or clogged. Do not 
allow foreign objects, such as cigarettes or napkins, to be sucked into the hood. 

 
WARNING: 

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 

 Never leave surface units unattended at high settings.    Boil overs cause smoking and greasy spillovers   

    that may ignite.    Heat oils slowly on low or medium settings. 

       

 Always turn hood ON when cooking at high heat or when greasy food. 

       

 Clean ventilating fans frequently.    Grease should not be allowed to accumulate on fan or filter. 

       

 Use proper pan size. Always use cookware appropriate for the size of the surface element.

 

 
WARNING: 

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP 

GREASE FIRE,   
            OBSERVE THE FOLLOWING: 
       

 

SMOTHER FLAMES

 with a close fitting lid, cookie sheet, or metal tray, then turn off the burner. Be 

careful  
            to prevent burns. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE 
DEPARTMENT. 
       

 NEVER PICK UP A FLAMING PAN - you may be burned. 

       

 DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. 

       

 Use an extinguisher ONLY if: 

            – You know you have a class ABC extinguisher, and you already know how to operate it. 
            – The fire is small and contained in the area where it started. 
      – The fire department is being called. 
            – You can fight the fire with your back to an exit. 

 

 

IMPORTANT SAFETY INSTRUCTIONS-

continue

Содержание PX01-W30

Страница 1: ...IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL INDOOR USE ONLY PRO X SERIES INSTALLATION GUIDE USER S MANUAL Models PX01 W30 PX01 W36 PX02 W30 PX02 W36 PX03 W30 PX03 W36 PX04 W30 PX04 W36 PX04 W42 Wall Mount Range Hood ...

Страница 2: ...t store flammable or explosive materials in adjacent cabinets or surrounding areas Disclaimer The manufacturer and or distributor reseller decline all responsibility in the event of failure to ob serve the instructions provided for installation maintenance and suitable use of the product The manufacturer and or distributor reseller shall NOT be responsible for any injury due to negligence and the ...

Страница 3: ...iring must be properly installed insulated and grounded Before servicing or cleaning unit turn power OFF and un plugged OPERATION Use high settings on cooking range only when necessary Keep all fan baffle spaces filter grease tunnel oil container and grease laden surfaces clean Grease should not be allowed to accumulate on fan baffle spaces filter grease tunnel and oil container Never allow the fi...

Страница 4: ...system must have a damper If roof or wall cap has a damper do not use damper supplied for some models only with the range hood For the most efficient quiet operation A distance of 26 to 30 is recommended between stove top and the bottom of range hood It is recommended that the range hood be vented vertically through the roof through 6 or bigger vent work ALWAYS when possible reduce the number or t...

Страница 5: ... CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances TOOL YOU WILL NEED Maker or pencil Stud finder Measuring tape Powered screwdriver or drill Flat Phillips screwdrivers Box level Drill with 1 8 drill bit Jigsaw or keyhole saw Cabinet Jack optional PARTS SUPPLIED 6 Anchors 2 or 3 Baffle Filters 1 Instruction manual book 1 Rem...

Страница 6: ...www XtremeAirUsa com PAGE 6 HOOD DIMENSIONS INSTALLATION OVERVIEW PX01 W30 PX01 W36 PX02 W30 PX02 W36 PX03 W30 PX03 W36 PX04 W30 PX04 W36 08 ...

Страница 7: ...ors and mounting screws make sure leaving 1 8 space away from the wall Step 3 4 Step 1 STEP 1 OPTIONAL ONLY Protect the cook top create work station Have 2 piece of wood stub about 2 x 4 x 20 on both sides of stove and a plywood on top of them to protect cook top or stove from damage or dirt This plywood will also create a comfortable work station for easy to install STEP 2 Marking on the wall 1 C...

Страница 8: ...hood body on the wall attaching it to the 2 screws already in place 2 Level the hood body by using horizontal level 3 Use hand screw driver to tight those 2 mounting screws 4 Connect the exhaust on the hood to the ductwork above Use a luminum tape to make all joints secure and all tight 5 Find the three pronged plug and connect to an electrical outlet CAUTION Do not release the hood yet until you ...

Страница 9: ...ng not the inner chimney 2 Place both the chimney on top of range hood base 3 Make sure the chimney is facing the correct direction PX02 outside chimney screw hole on the bottom Inside chimney screw hole on the top PX01 PX03 PX04 inside chimney screw hole on the top 4 Secure outside chimney to the base of the hood PX02 ONLY 5 Attach the inside chimney to the ceiling mounting bracket 6 Screw the ch...

Страница 10: ...f inactivity A Activating Normal Blower Function B Activating Light Function C Activating Power Off Delay Function Touch Light button to turn the lights on or off 1 While the range hood is on and the blower is running in normal mode touch Power Off Delay button to activate delay off timer 2 Adjust to desired period of delay of timer by touching or button 1 15 minutes Timer begins to countdown imme...

Страница 11: ...F lights 8 8 Indicates the accumulated time the system is running 9 9 Indicates the length of time left for delay off function 10 10 Lights up when auto shutdown delay timer function is on A Activating Blower Function Option 1 Touch and hold down for 1 2 seconds Option 2 Touch and hold down power sign 1 for 1 2 seconds the blower will be running as the same speed as last used Note The system saves...

Страница 12: ...e cumulative running time will be shown in Power On Elapsed Digital Timer This timer icon flashes when 30 hours is up and reminds user to clean the baffle filters After cleaning the filters and when the motor is not in use touch and hold Increase Value button over 3 seconds to reset the timer Please note that turning off the system will not reset the Power On Elapsed Digital Timer F AUTOMATIC SHUT...

Страница 13: ... work but the blower is not spinning at all is stuck or is rattling The blower might be jammed or scraping the bottom due to shipping damage Please contact us immediately The motor is defective possibly seized change the motor 5 The hood is not venting out properly Make sure the distance between the stove top and the bottom of the hood is within 26 and 30 in distance Due to different ceiling heigh...

Страница 14: ... cotton cloth Do not use corrosive or abrasive detergent e g Comet Power Scrub EZ Off oven cleaner or steel wool scoring pads which will scratch and damage the stainless steel surface For heavier soil use liquid degrease such as Formula 409 or Fantastic brand cleaner If hood looks splotchy stainless steel hood use a stainless steel cleaner to clean the surface of the hood Avoid getting cleaning so...

Отзывы: