The telehandler is not electrically insulated. Death or serious injury will result from contact
with, or inadequate clearance from, an energized conductor.
Do not go closer than the minimum safe approach distance as defined by the Minimum Safe
Approach Distance sections in Chapter 3–Safety.
Regard all conductors as energized.
Allow for electrical wire sag and telehander sway.
If the carriage, booms, or any part of the telehandler contacts a high-voltage electrical conductor, the
entire machine can become electrically charged.
If that happens, remain on the machine and do not contact any other structure or object. This includes
the ground, adjacent buildings, poles, and any other objects that are not part of the aerial platform.
Such contact could make your body a conductor to the other object, creating an electrical shock hazard
resulting in death or serious injury.
If a telehandler is in contact with an energized conductor the operator must warn ground personnel
in the vicinity to stay away. Their bodies can conduct electricity creating an electrical shock hazard
resulting in death or serious injury.
Do not approach or leave the telehandler until the electricity has been turned off.
Do not attempt to operate the controls when the carriage, booms, or any part of the telehandler is in
contact with a high-voltage electrical conductor or if there is an immediate danger of such contact.
Personnel on or near the telehandler must be continuously aware of electrical hazards, recognizing
that death or serious injury can result from contact with an energized conductor.
California
Proposition 65 Warning
Battery posts, terminals, and related accessories contain
lead and lead components, chemicals known to the
State of California to cause cancer and birth defects or
other reproductive harm. Wash hands after handling.
California
Proposition 65 Warning
Diesel and gasoline engine exhaust and some of its con-
stituents are known by the State of California to cause
cancer, birth defects or other reproductive harm.
Pre-delivery Inspection Report must be completed upon placing
unit in service. Please use QR link or visit
www.xmfg.com/warranty/pre-delivery-inspection-report
to register on-line.
Содержание XR5919-A
Страница 1: ...October 2020 Part Number 24978 001 MANUAL Tier 3 and Tier 4 Final OPERATION AND SAFETY QRGOVSALES ...
Страница 4: ...XR5919 A ...
Страница 10: ...Chapter 1 Introduction 4 XR5919 A ...
Страница 12: ...Chapter 2 Specifications 6 XR5919 A ...
Страница 54: ...Chapter 5 Pre Operation Inspection 48 XR5919 A ...
Страница 66: ...Chapter 6 Operation 60 XR5919 A ...
Страница 68: ...Chapter 7 Emergency Lowering 62 XR5919 A ...
Страница 72: ...Chapter 9 Lockout Tagout 66 XR5919 A ...