background image

4445102761

01/2019

For service/technical enquiries: 

 

1800 212121

XTM40-O-AUS.book  Seite 24  Montag, 7. Januar 2019  2:30 14

Содержание XTM40

Страница 1: ...Operating manual Compressor Fridge Freezer 40 LITRE AC DC XTM40 XTM40 O AUS book Seite 1 Montag 7 Januar 2019 2 30 14...

Страница 2: ...XTM40 O AUS book Seite 2 Montag 7 Januar 2019 2 30 14...

Страница 3: ...g with it The manufacturer cannot be held liable for damage resulting from improper usage or incorrect operation Contents 1 Explanation of symbols 4 2 Safety instructions 4 3 Scope of delivery 7 4 Int...

Страница 4: ...device on boats If the device is powered by the AC mains ensure that the power supply is protected with a ground fault interrupter circuit DANGER Safety instruction Failure to observe this instructio...

Страница 5: ...by children without supervision Children must not play with the device Children must be supervised to ensure that they do not play with the device Always keep and use the device out of the reach of c...

Страница 6: ...g the device safely CAUTION Before starting the device ensure that the power supply line and the plug are dry A NOTICE Do not use electrical devices inside the cooler unless they are recommended by th...

Страница 7: ...2 1 Connection cable for DC connection 3 1 Connection cable for AC connection 4 2 Carrying handle consisting of 2 holders 1 handle 4 fastening screws 1 Powdercoated steel basket 1 Protective cover 1 O...

Страница 8: ...ses clients in hotels motels and other residential type environments bed and breakfast type environments catering and similar non retail applications 5 Function description Thecoolercan refrigerate or...

Страница 9: ...y monitor to protect the vehicle battery Turbo mode for rapid cooling Display with temperature gauge switches off automatically at low battery voltage Temperature setting two buttons in steps of 1 C 2...

Страница 10: ...ssor is off LED flashes orange Display switched off automatically due to low battery voltage 3 ERROR LED flashes red Device is switched on but not ready for operation 4 SET Selects the input mode Temp...

Страница 11: ...sockets Item in fig 4 Description 1 AC voltage supply inlet 2 Fuse holder 3 DC voltage supply inlet 4 Emergency switch 100 240V AC FUSE 12 24V DC EMERGENCY OVERRIDE NORMAL USE 4 1 2 3 4 XTM40 O AUS bo...

Страница 12: ...ure units You can switch the temperature display between Celsius and Fahrenheit This is how to do it Switch on the cooler Press the SET button fig 3 4 page 10 twice Use the UP fig 3 6 page 10 and DOWN...

Страница 13: ...r boat The cooler can be operated with 12 Vg or 24 Vg A For safety reasons the cooler is equipped with an electronic system to prevent polarityreversal Thisprotectsthecooleragainstshort circuitingwhen...

Страница 14: ...charging when the device is connected to an on board DC supply Ifthecooleris operated when the vehicleignition is switched off thecoolerswitches off automatically as soon as the supply voltage falls b...

Страница 15: ...he display flashes several times before it returns to the current temperature I Battery monitor mode LOW MED HIGH Switch off voltage at 12 V 10 1 V 11 4 V 11 8 V Restart voltage at 12 V 11 1 V 12 2 V...

Страница 16: ...rated during operation can dissipate Ensure that the ventilation slots are not covered The cooler MUST maintain a MINIMUM of 50 mm away from wallsor similar surfaces which could restrict important air...

Страница 17: ...in the connection panel For normal operation the switch should be in the NORMAL USE position In the unlikely event of an electronic control failure slide the switch to EMERGENCY OVERRIDE I 6 8 Switchi...

Страница 18: ...the lid open Wipe off the defrosted water 6 10 Replacing the AC fuse D Pull off the connection cable Pry out the fuse insert fig 4 2 page 11 with a screwdriver Replace the defective fuse with a new on...

Страница 19: ...Take out the contact pin 3 Replace the defective fuse 2 with a new fuse of the same type and rating 8 A 32 V Re assemble the plug in the reverse order I NOTE Internal DC fuse There is an additional D...

Страница 20: ...that the air inlet and outlet vents on the device are free of any dust and dirt so that heat can be released and the device is not damaged NOTE The LEDs in the light bulb must be facing the transparen...

Страница 21: ...e Fault Possible cause Suggested remedy Device does not function LED does not glow No voltage was detected in the DC power outlet In most vehicles the ignition must be turned on before power will be s...

Страница 22: ...either the DC outlet must be cleaned or the plug has not been assembled correctly The fuse of the DC plug has blown Replace the fuse in the DC plug see chapter Replacing the DC plug fuse on page 19 T...

Страница 23: ...olume 39 l Storage volume 37 l Climate class N or T Ambient temperature 18 C to 43 C 50 F to 109 4 F Noise emission 45 dB A Refrigerant quantity 45 g CO2 equivalent 0 059 t Global warming potential GW...

Страница 24: ...4445102761 01 2019 For service technical enquiries 1800 212121 XTM40 O AUS book Seite 24 Montag 7 Januar 2019 2 30 14...

Отзывы: