background image

6

7

MAINTAIN YOUR GENERATOR WITH 

CARE

When not using your generator ensure the fuel cock is 
‘OFF’. Never leave the fuel cock ‘ON’ as this can damage 
the carburettor. Follow the instructions for lubricating and 
changing accessories. Keep handles clean, dry and free from 
oil and grease. Ensure that ventilation slots are kept clean 
and free from dust at all times. Blocked ventilation slots can 
cause overheating and damage to the motor. Ensure that the 
air and fuel filters are kept clean at all times.

REMOVE ADJUSTING KEYS AND 

WRENCHES

Form the habit of always checking to see that any adjusting 
keys or wrenches have been removed from the generator 
before operating.

CLEANING YOUR GENERATOR

Always stop your generator before you commence cleaning. 
Always ensure that your generator has cooled, about one 
(1) hour, before cleaning and storing. When cleaning your 
generator use only a damp soft cloth. NEVER use liquid or 
solvents of any type. All areas can be wiped down. 

EXTENSION CORDS & REELS

Inspect extension cords periodically and replace if damaged. 
Never use damaged extension cord as these may cause 
injury. Always unwind any extension cords fully before 
plugging into mains power supply. Protect your extension 
cord or reel from sharp objects, excessive heat, damp 
conditions or wet locations. Always use a ‘3’ core extension 
cord or reel with this generator. Only heavy duty extension 
cords intended for and marked ‘outdoor’ use, which are no 
longer than 20m.

SELECT A GENERATOR WITH A 

SUFFICIENT RATING

Select the right generator for the job. Do not use a generator 
to do a job for which it was not designed. Do not force a 
small generator to do the job of a heavy duty generator. Any 
damage caused by overloading will void the warranty. Do not 
use generators for purposes not intended. 

PROTECT POWER LEADS FROM 

DAMAGE

Always disconnect power cords from a power supply 
socket by pulling the plug. Never pull on the cord. Keep the 
power lead away from heat, oil, solvents and sharp edges. 
If a power lead becomes damaged have it replaced by an 
authorised service facility.

FIRE PRECAUTIONS

Always contact your fire authority before using the 
generator on fire restricted days. It is not recommended 
to use your generator when a total fire ban is in force. 
Never refuel your generator while it is still running. Never 
connect your generator to a commercial or domestic power 
outlet. As a precaution it is recommended that an expert is 
consulted on obtaining and using a suitable fire extinguisher.

CHECK DAMAGED PARTS

Before using the generator it should be carefully checked 
to determine that it will operate properly and perform its 
intended function.

Check for broken or missing parts and have them replaced 
or repaired at an authorised service facility. Check any other 
condition that may affect the operation of the generator. A 
guard or any other part of the generator that is damaged 
should be properly repaired or replaced by an authorised 
service facility unless otherwise indicated in this instruction 
manual.

Any switch that does not operate correctly must be 
replaced by an authorised service facility.

DO NOT use the generator if the ‘ON / OFF’ motor switch 
does not turn the generator ‘ON’ and ‘OFF’.

Содержание XTM2000DG

Страница 1: ...ENGINE OIL AND WILL NOT START UNTIL FILLED TO THE CORRECT LEVEL Oil type 4 stroke fully synthetic motor oil SAE 15W 40 API SN Category Oil Capacity 400ml Approximately Refer to page 8 and page 10 wit...

Страница 2: ...se attach the purchase receipt to this manual and ensure both are kept safe We hope you enjoy your new generator and if you have any problems call customer service on the above phone numbers Do not re...

Страница 3: ...g and trouble free service life from your generator This generator is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and...

Страница 4: ...nformation please contact customer service Australia 1300 660 457 New Zealand 0800 474 876 CONTACT DETAILS Smart Marketing Group Pty Ltd 33 35 Lionel Road Mt Waverley Victoria 3149 Australia Tel 613 9...

Страница 5: ...oolant on the generator as a fatal electric shock could occur Never use coolant in the generator as damage may occur Do not touch the generator with wet hands as this may cause electrocution Never use...

Страница 6: ...moving machinery Gloves may be worn when filling generator with fuel Hair Long hair should be tied back or contained in a protective covering Eye Protection The use of safety goggles is highly recomm...

Страница 7: ...elect the right generator for the job Do not use a generator to do a job for which it was not designed Do not force a small generator to do the job of a heavy duty generator Any damage caused by overl...

Страница 8: ...store your unleaded petrol ULP in before decanting into the fuel tank If contaminated dirty or old stale fuel is used any damage caused will not be covered under warranty OIL CHECK DAILY ONLY USE 4 S...

Страница 9: ...indicator red This indicator light is on when the generator is overloaded when the red light turns on the power supply will be automatically disconnected Check the attached products power requirement...

Страница 10: ...at the bottom 3 Use oil as detailed on page 8 4 stroke fully synthetic motor oil SAE 15W 40 API SN Category 4 Ensure generator is level when filling with oil DO NOT TIP USE A FUNNEL NOT SUPPLIED 5 Rem...

Страница 11: ...ON 1 Ensure the Earth stake and wire are attached Pic 5 2 Turn the fuel cap breather lever clockwise to ON Note If fuel cap breather is not on generator will not operate correctly 3 Turn the fuel tap...

Страница 12: ...witch economy smart switch to OFF Pic 11 4 Turn fuel tap and engine switch clockwise to OFF Pic 12 PIC 10 PIC 11 PIC 12 PIC 9 WARNING Never pull the recoil once the engine has started Any damage cause...

Страница 13: ...he problem before using the generator 2 Lift the flap and plug your appliance into the outlet socket on the face plate 3 Turn the appliance on and use as per the manufacturers manual 4 When finished t...

Страница 14: ...nce s required power is greater than the generator s output check the appliances wattage requirements refer Page 13 Output indicator light green will remain ON during operation However if it goes out...

Страница 15: ...d fuel responsibly 6 Fit access panel at the bottom then position at top and secure with screws 2pcs 1 Remove fuel tank cap 2 Remove the fuel tank filter 3 Position a fuel safe container next to the g...

Страница 16: ...for cracks or damage Replace if required Exhaust system Check for leakage Tighten or replace gasket if required Check exhaust screen Clean and replace if required Carburettor Check choke operation Fi...

Страница 17: ...properly gapped and free of deposits in order to ensure proper engine operation To check 1 Remove the spark plug cover 2 Remove the spark plug cap Pic 18 3 Clean any dirt from around base of spark pl...

Страница 18: ...enerator to drain the oil out of the oil fill 8 Once oil sump is empty place generator on its feet wipe up any spills 9 Replace oil filler cap If changing oil refer to page 10 for oil filling details...

Страница 19: ...pplied with fuel Poor spark Pull Recoil Quickly Clean tank Clean fuel line Fill with Correct Fuel See Page 8 Rotate START Switch to ON Spark plug dirty with carbon or wet with fuel Clean spark plug Da...

Страница 20: ...onsult Service Agent Generator problem Indicator light OFF No AC output Output power too high or low EngineRPM set too highor low Consult Service Agent Loose Consult Service Agent t n e n o p m o c In...

Страница 21: ...TER SPARK PLUG Authorised Service Agent Name or Company Stamp Technician Date This service is to be completed within 36 hours or 9 months of purchase which ever comes first REPLACE CHECK ADJUST ENGINE...

Страница 22: ...22 This page has been left intentionally blank...

Страница 23: ...ATEGORY Fuel tank capacity 4 2L Fuel type Unleaded 91 Petrol no ethanol Spark plug A7RTC Rated voltage 230 240V AC 50Hz Rated output 1800W Maximum output 2000W Rated current 7 5A Power factor 1 0 Maxi...

Страница 24: ...ROUP AUSTRALIA PTY LTD Mon Fri 8 00am 5 00pm AEST Do not return to place of purchase Keep your purchase receipt this will be required to make any claims under the 12 month warranty Australia 1300 660...

Отзывы: