11
5.4.2.
PROGRAM
>
[4] Information
Items
Descriptions
Format
-1. Hardware version
To show the Door Station(including ACS)
hardware
information
[MR-V5, ACS-V3]
-2. Software version
To show the Door Station(including ACS)
software
information
[MR-V7, ACS-V2]
-3. Manufacture Date
To show the Door Station
manufacturing date
[YY-MM-DD]
-4. Dialing Counts
To show the Door Station
call operation counts
[0000]
-5. Calls Counts
To show the Door Station
established calling counts
[0000]
-6. Unlock Counts
To show the Door Station
unlock operation counts
[0000]
5.4.3.
PROGRAM
>
[5] Operating Options
Items
Descriptions
Factory setting
-1. Diagnose Range
To set the valid room codes range in system, for the purpose of
IDS software device management. Monitors out of limit range
will not be inspected.
[0101~1604]
-2. Upload Log
If set to 1, system operating logs will be sent to IDS software; If
set to 0, logs will not be sent.
[0]
Don’t transmit
-3. Voice Guide
To select the language of voice guide inside the Door Station.
If set to 0, no voice guide is activated; set to 1, use Chinese voice
guide; Set to 2, use English voice guide; Set to 3, use Korean voice
guide; Set to 4, use customized language voice guide.
[0]
No Voice guide
-4. Multi Channel
To configure system audio/video channel number.
If set to 0, single channel, when F4(A) or no distributor are installed;
If set to 1, four audio channels, and F4Q distributor should be used;
If set to 2, four audio and dual video channels, when F4QV is used;
If set to 3, dual audio channels, and F4D distributor should be used;
If set to 4, dual audio&video channels, and F4DV should be used.
[0]
Single channel
-5. Extend Monitors
To configure system if extended Monitors are installed in one unit,
and extended Monitors have the same Room code. If set to 0, only 1
Monitor in one unit; set to 1, total is 1 monitor in this unit, 1 extended
Monitor can be installed, total is 2 Monitors in this unit; set to 2, 2
extended Monitors can be installed, total is 3 monitors in this unit.
[0]
No extended
-6. Door Open Alert
To configure send alert to Guard Unit if door is open all the while. If
set to 1, alert if door opened more than 90s; set to 0, don’t alert.
[0]
Disable
-7. Monitor&Speak
To enable Indoor Monitor under monitoring state can speak to Door
Station at same time. If set to 1, talk enabled; set to 0, disabled.
[0]
Disable
To enable Monitors under monitoring state can open the door at
-8. Monitor&Unlock
same time.If set to 1, unlock function is enabled; set to 0, disable.
[0]
Disable
To select the Door Station screen menu in standby.
-9. Display Mode
If set to 1, use customized menu; set to 0, use default menu.
[0]
Default menu