265 Prado Road, Suite 1 | San Luis Obispo, CA 93401 | 805.541.0100 | xpressfill.com | [email protected]
21
| XpressFill Systems LLC
Pressure Adjustment Knob Deep-Cleaning Instructions
Remove the pressure relieve valve from the filler. Use
the release tool provided to disconnect the push-to-
connect fittings from the tubes.
Turn the knob counterclockwise until you feel a
resistance and push down (lock position). Unscrew the
black plastic housing (including knob) from the brass
base. It is not necessary to unscrew the tubing adaptors
from the brass base.
Now rinse out all the openings inside and outside of the
valve, removing any particulates and stickiness that
may have accumulated.
Reassemble and replace in the filler.
The Brass body is marked “IN” on one side. This is
the input side.
Note:
This maintenance is needed only when the filler is not performing properly.