Spare Fuse
There is a spare fuse in the power entry connector (where the power cord plugs in). Unplug the machine and set a
screwdriver on the notch (do not remove screws) and pop the spare fuse holder toward you, then replace the fuse.
XpressFill Part No. 200002 - Bussmann Series by Eaton, Model BK/GDB-2A, 5mm x 20mm
Delay-Timer Adjustment
Each spout has two delay timers.
To adjust time, turn the blue knobs with
the arrow counter clockwise to reduce the
purge time or clockwise to increase purge
time.
The top delay timers control the time of
CO2 flow.
The bottom delay timers control the time
the vent solenoid is open, purging the
bottle.
Note:
The top timer should always be set
for a bit longer than the lower timer,
allowing the bottle to pressurize.