Flip the Fill Switch to the full up position.
The filler will purge the bottle for a few
seconds, after which the Bottle Foot Rest will
immediately lift the bottle into a sealing
position against the stopper and pressurize
the bottle.
14.
After the purge and bottle pressurization, the fill
light will come on and liquid begins to flow into
the bottle. If no flow is visible, then the Pressure
Relief needs adjustment. See Adjusting Pressures
in the following section.
15.
Once the green fill light deactivates, put the Fill
Toggle Switch to the middle position (
do not
flip
to the full down position) and pull the Pressure
Release Knob.
18.
Hold the bottle with one hand and flip the Fill
Toggle Switch to the full down position to
release air in the pneumatic ram and remove the
bottle.
19.
You are now ready to place a bottle on your
machine. While pressing down on the Bottle
Foot Rest, place a bottle on the Bottle Foot
Rest and allow the return spring to
lightly
hold the bottle against the stopper.
Note: During the purge process, the bottle
will temporarily unseat from the stopper to
allow air to escape.
Make sure the Pressure Release Knob is pushed in.
Always keep your hands clear of the bottle and
foot rest during step 17.
16.
17.
Repeat steps 15 - 18
for the other spouts.
Congratulations!
You have now filled your first bottles
using the XF4500 Filling System.
Plug the hose from your liquid container
into the port marked “Inlet” on the left side
of the machine using one of the provided
3/8” barbed fittings.
See “Adjusting Pressure” on page 7.
Plug one end of the provided 4’ x 1/4” tube
into the port marked “Vent” on the left side
of the machine, and place the other end into
your catch basin.
Plug your air compressor into the port
marked “Air” on the left side of the machine
using one of the provided 1/4” barbed fittings.
See “Adjusting Pressures” on page 7.
Plug your CO2 tank into the port marked
“CO2” on the left side of the machine using
one of the provided 1/4” barbed fittings.
9.
Once you are sure that all components are
plugged in correctly, you can open the valves
on your tanks and turn on the air compressor.
10.
Turn on your machine by flipping the power
switch on the right side of your machine so
that is it lit up.
11.
12.
13.
Vent
CO2
Air
Inlet
Cleaning switches
20.
The valves on the tanks should
be off for steps 9-11.