background image

 

XPRESSFILL Systems LLC

 | 

9

265 Prado Road, Suite 1  •  San Luis Obispo, CA 93401  •  Tel: (805) 541-0100  •  [email protected]

Cleaning

Cleaning your XpressFill is quick and easy, and is the single most important maintenance you can 
administer to ensure long life and solid performance from your fi ller. Please use extreme caution 
when using any cleaning product.

For general cleaning, we highly recommend a product called PBW by Five Star Chemicals. It 
is safe, fast, and eff ective, and our customers have been happy with the results.  To clean your 
XpressFill, begin by fl ushing your fi ller with 2 gallons of plain warm (not boiling) water from a 
pressurized keg, which is pressurized with air. Follow that with a 3-gallon mix of PBW cleaner, 
and let the PBW sit inside your fi ller for a few minutes in order to do its cleaning job. Follow the 
cleaning with a sanitizer.

For sanitizing, we recommend Saniclean, from the same manufacturer. Saniclean has low-
foaming characteristics, is highly eff ective, and completely food grade if diluted correctly per the 
manufacturer’s instructions. Use the sanitizer with about 3 gallons of water, and follow the steps 
according to the manufacturer’s instructions. After sanitizing, fl ush your fi ller with 2 gallons of 
warm water. Before storing your XpressFill fi ller, make sure you get all water out of the fl ow path. 
Allow to run until pressurized keg with cleaning solution is empty and runs dry, blowing the 
remaining water out of the fi ller vent.

See instructions on the following page.

1

2

3

4

5 6

7

8

Содержание XF4500

Страница 1: ...XpressFill XF4500 Counter Pressure Filler Operating Instructions...

Страница 2: ...of the bottle filling machine can result in serious injury or death Do not use the machine in any way not covered in this manual or for any purpose other than those explained in the following pages S...

Страница 3: ...Safety Warnings iii XPRESSFILL Systems LLC...

Страница 4: ...b u o r T 6 9 r e l l i F r u o Y g n i n a e l C XpressFill Product Guarantee e filler will be repaired or replaced if upon inspection at the factory the filler is found to be defective in materials...

Страница 5: ...nob 2 Fill toggle switch 3 position 3 4 5 1 2 3 4 5 6 8 7 9 The below diagram highlights the important features on your ller which will be referenced throughout this manual Being familiar with each of...

Страница 6: ...et will hold your bottle securely in place once the ll sequence is started Do not put your hands between the bottle and the foot to prevent injury 6 Upper Spout is spout is used for the gas ush and ll...

Страница 7: ...CO2 Regulator 3 CO2 Line to Keg Inlet 4 Pressurized Keg 5 Line to Inlet input on Filler 6 CO2 line to CO2 input on Filler 7 Compressed are line to Air input on Filler 8 3 Setting Up Your Filler and F...

Страница 8: ...cleaning switches on the left side are in the down position Fill Mode 3 Toggle the ll switches to the full up position Start Fill Position Wait a few seconds to verify that the green fill light illumi...

Страница 9: ...ring the purge process the bottle will temporarily unseat from the stopper to allow air to escape Make sure the Pressure Release Knob is pushed in Always keep your hands clear of the bottle and foot r...

Страница 10: ...ing will trigger the fill sensors and stop filling prematurely The bottle will begin filling again as the foam settles but this significantly slows down the filling rate 2 Typical maximum inlet pressu...

Страница 11: ...Adjustment Knob clockwise will increase the bottle pressure and reduce foaming The higher the bottle pressure and lower the temperature the more CO2 will stay in solution The XF4500 is a Level Fill ma...

Страница 12: ...ressurized with air Follow that with a 3 gallon mix of PBW cleaner and let the PBW sit inside your ller for a few minutes in order to do its cleaning job Follow the cleaning with a sanitizer For sanit...

Страница 13: ...essure release knob on top counter clockwise to open up the valve for fast flow 5 Let solution fill the bottle completely and allow it to run for a while after full 6 Turn the spout switch to the midd...

Страница 14: ...filling system 4 Turn spout switch to middle position and then back up to full on position Repeat this several times to allow the purge path to ventilate completely 5 Turn the release pressure knob at...

Страница 15: ...r fillers use Push To Connect type connectors which are standard in the beverage industry 1 Installation simply requires pushing a tube into the fitting and pulling lightly to check that the connectio...

Отзывы: