XpressFill XF4500 Скачать руководство пользователя страница 2

ii

 | 

XPRESSFILL Systems LLC

265 Prado Road, Suite 1  •  San Luis Obispo, CA 93401  •  Tel: (805) 541-0100  •  [email protected]

 lling machine.

  ank you for choosing our handcrafted bottle fi ller as the technology to bottle your passion.  We 

look forward to assisting you in experiencing the best performance from your fi ller.

  is manual is written with your safety and convenience in mind.  We highly recommend reading 

the manual before using your fi ller for the fi rst time.

If you have any questions or comments, please do not hesitate to contact us.

XpressFill Systems LLC

265 Prado Road, Suite #1

San Luis Obispo, CA 93401

USA

(805) 541-0100

 ll.com

 ll.com

Important Safety Instructions

Misuse of the bottle-fi lling machine can result in serious injury or death.  Do not use the machine 
in any way not covered in this manual or for any purpose other than those explained in the 
following pages.

Severe product damage and/or injury could result from the use of unqualifi ed Service 
Technicians or non-original replacement parts.  All repairs must be performed by a qualifi ed 
Service Technician or with the approval from an XpressFill Technician.  Only original factory 
replacement parts should be used.

Electrical shock or fi re could result if the electrical supply for the bottle fi ller covered in this 
manual is not correctly installed or if the bottle fi ller has been improperly grounded.  Do not 
use the bottle fi ller covered in this manual unless you are certain the electrical supply has been 
correctly installed and the bottle fi ller has been properly grounded.

Содержание XF4500

Страница 1: ...XpressFill XF4500 Counter Pressure Filler Operating Instructions...

Страница 2: ...of the bottle filling machine can result in serious injury or death Do not use the machine in any way not covered in this manual or for any purpose other than those explained in the following pages S...

Страница 3: ...Safety Warnings iii XPRESSFILL Systems LLC...

Страница 4: ...b u o r T 6 9 r e l l i F r u o Y g n i n a e l C XpressFill Product Guarantee e filler will be repaired or replaced if upon inspection at the factory the filler is found to be defective in materials...

Страница 5: ...nob 2 Fill toggle switch 3 position 3 4 5 1 2 3 4 5 6 8 7 9 The below diagram highlights the important features on your ller which will be referenced throughout this manual Being familiar with each of...

Страница 6: ...et will hold your bottle securely in place once the ll sequence is started Do not put your hands between the bottle and the foot to prevent injury 6 Upper Spout is spout is used for the gas ush and ll...

Страница 7: ...CO2 Regulator 3 CO2 Line to Keg Inlet 4 Pressurized Keg 5 Line to Inlet input on Filler 6 CO2 line to CO2 input on Filler 7 Compressed are line to Air input on Filler 8 3 Setting Up Your Filler and F...

Страница 8: ...cleaning switches on the left side are in the down position Fill Mode 3 Toggle the ll switches to the full up position Start Fill Position Wait a few seconds to verify that the green fill light illumi...

Страница 9: ...ring the purge process the bottle will temporarily unseat from the stopper to allow air to escape Make sure the Pressure Release Knob is pushed in Always keep your hands clear of the bottle and foot r...

Страница 10: ...ing will trigger the fill sensors and stop filling prematurely The bottle will begin filling again as the foam settles but this significantly slows down the filling rate 2 Typical maximum inlet pressu...

Страница 11: ...Adjustment Knob clockwise will increase the bottle pressure and reduce foaming The higher the bottle pressure and lower the temperature the more CO2 will stay in solution The XF4500 is a Level Fill ma...

Страница 12: ...ressurized with air Follow that with a 3 gallon mix of PBW cleaner and let the PBW sit inside your ller for a few minutes in order to do its cleaning job Follow the cleaning with a sanitizer For sanit...

Страница 13: ...essure release knob on top counter clockwise to open up the valve for fast flow 5 Let solution fill the bottle completely and allow it to run for a while after full 6 Turn the spout switch to the midd...

Страница 14: ...filling system 4 Turn spout switch to middle position and then back up to full on position Repeat this several times to allow the purge path to ventilate completely 5 Turn the release pressure knob at...

Страница 15: ...r fillers use Push To Connect type connectors which are standard in the beverage industry 1 Installation simply requires pushing a tube into the fitting and pulling lightly to check that the connectio...

Отзывы: