6. CONNECTING BIOMETRIC READERS TO THIRD PARTY CONTROLLERS
BIOMANAGER Software
RS485
A
RS485 B
A
B
3rd party controller
- + D0 D1
- + D0 D1
3rd party controller
- + D0 D1
- + D0 D1
CNV100
CNV200
CNV300
BIOE
USB Desktop Reader
optional
Connect the lines D0, D1, Gnd and +12V to the third party controller.
Connect the RS485 Line (A, B) to the converter. Connect the converter in the PC.
Fingerprint enrollment is done from the PC Software. Connection between the Biometric readers and the PC must be established.
The Biometric readers communicate with each other with a RS485 and with the PC Software through a Converter.
The RS485 Line should be configured in the form of a daisy chain, NOT in a form of a star. Keep the stubs from the RS485 backbone
as short as possible (not more than 5 meters)
Only one converter per installation is needed, not per reader.
Biometric Reader
Converter
RS 485 A
RS 485 B
PIN 1 (RS 485 +)
PIN 2 (RS 485 -)
CNV100
Converter RS485 to RS232
Does not requires installation
CNV200
Converter RS485 to USB
Requires installation as USB serial
device (refer to CNV200 Manual). The
Drivers are located on the CD.
CNV300
Converter RS485 to TCP/IP
Does not require installation. IP
address set through Internet
Browser(refer to CNV300
Manual)
6.1 CONVERTERS PIN DESCRIPTION
PIN 1
PIN 1
PIN 1
7
www.visual-plus.com