10. EXAMPLES
11. PROGRAMMING WITH KEYPAD(LCSP, VKP, INOX,MTPAD-M)
Task1:
Task2:
Task3:
Make
1 Door installation
with 1 Reader. Enroll 2 users to open the door.
Make
1 Door installation
with IN and OUT Reader. Enroll User1 with access to Door1 in Anti Pass Back Mode and additional
User2 that will not have access to Door1, but will be able to turn the lights in the office ON/OFF.
Make
2 Door installation
. Enroll User 1 to open only DOOR1 and User 2 to open DOOR2 and User3 to open Door1 and Door2.
DIP switch settings:
all are OFF
1. Present Master1 Card
2. Present Shadow Card
3. Present User Card 1
4. Present User Card 2
4. Present Master1 Card
DIP switch settings:
No.4-ON, all other are OFF
DIP switch settings:
7 - ON; all others OFF
Relay connection:
Door relay1 - Door Lock; Door Relay 2 - Lights Main Switch
Relay connection:
Door relay1 - Door Lock; Door Relay 2 - Door Lock
1. Present Master1 Card
2. Present Shadow Card 1
3. Present User Card 1
4. Present Master1 Card
1. Present Master1 Card
2. Present Shadow Card 1
3. Present User Card 1
4. Present Master1 Card
1. Present Master2 Card
2. Present Shadow Card 2
3. Present User Card 2
4. Present Master2 Card
1. Present Master2 Card
2. Present Shadow Card 2
3. Present User Card 2
4. Present Master2 Card
1. Present Master 2 Card 3 times
2. Present Master 2 Card
1. Present Master1&2 Card
2. Present Shadow Card 3
3. Present User Card 3
4. Present Master1&2 Card
User1 with Access to Door1
User1 with Access to Door1
User2 to be able to activate
Door Relay2 (Lights), but not
Door Relay 1.
User2 with Access to Door2
Make Door relay 2 to work in ON/OFF Mode
User3 with Access to Door1 and Door2
The programming with Keypad is
same
as programming with proximity reader.
Please refer to programming explained on
pages 4 to 7
, just replace the word “
Card
” with “
PIN Code
”
Keypad settings
Set the keypad to be compatible with SC24000 Standalone Controller
Press
B+000000
to enter the menu
Press
6
Press
1
Press
A
to exit the menu
This will set the Keypad in “Wiegand26 bit Normal”, “4 Digits PIN Code” and “Card or PIN Code” mode(LCSP).
For other settings (like changing PIN Code length), please refer to the keypad’s manual.