www.xprgroup.com
3
4. TERMINAL BLOCK DESCRIPTION
5. DIP SWITCH SETTINGS
led’s
power supply
wiegand
led’s
power supply
wiegand
(NC)
(NO)
(NC)
(NO)
Led Green -
Led Red -
GND
12 VDC
Data0
Data1
12 VDC
GND
12 VDC
GND
Led Green -
Led Red -
GND
12 VDC
Data0
Data1
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
Door Sensor 1
GND
Push Button 1
Door Sensor 2
GND
Push Button 2
Reader 1
Power Supply
Reader 2
Door 1 Relay
Door Left Open Alarm
Forced Door Alarm
Door 2 Relay
Door Sensors
Exit Buttons
Alarm Outputs
Output 1
(door left open alarm)
- ON if any door is left open by the time set in:
”Set door left open Alarm”
- OFF when door is closed
Output 2
(forced door alarm)
- ON if any door is open by force
- OFF when the door is closed
NOTE:
If Door Sensors are not being used, the terminal
blocks Door Sensor1 and Door Sensor 2 should be
shorted with GND. By factory default, the controller will
be delivered with shorted Door sensors.
NOTE:
Do not connect different Wiegand type of
readers. Both readers should be either Wiegand 26bit or
Wiegand 34bit.
1 2 3 4 5 6 7 8
ON
NOTE:
Double wiegand is used for double security(Card + PIN Code). When LCSP-EM/MF is connected and LCSPEM/-
MF is set in double security mode, put the dipswitch 1 or 2 to position ON.
NOTE:
If Door sensors are not used, dipswitch No.3 should stay OFF.
NOTE:
In 1 Door Mode, both readers are assigned to Door1. User Card can be programmed to trigger both relays,
which gives the option the second door relay to be used as alarm.
1
2
3
4
5
6
7
8
ON
Double
Wiegand
on Reader 1
Double
Wiegand
on Reader 2
APB
follow
sensor ON
Anti Pass
Back option
ON
Enroll
Master Card
ON
Factory
Reset
ON
2 DOOR
Mode
Not used
OFF
Single
Wiegand
on Reader 1
Single
Wiegand
on Reader 2
APB
follow
sensor OFF
Anti Pass
Back option
OFF
Enroll
Master Card
OFF
Factory
Reset
OFF
1 DOOR
Mode
Not used