www.xprgroup.com
1
2 Door standalone access control unit
EN
SC24000
CONTENTS:
1. FEATURES
1.
Features
.................................................................................................. 1
2.
Mounting
.................................................................................................. 2
3.
Typical two door application
.......................................................... ............. 2
4.
Terminal block description
....................................................................... 3
5.
DIP switch settings
.................................................................................... 3
6.
Wiring
................................................................................................. 4
7.
Factory reset
.................................................................................... 4
8.
Programming
.................................................................................... 5
9.
Anti Pass Back
.................................................................................... 7
10.
Examples
................................................................................................. 8
11.
Programming with Keypad (LCSP, VKP, INOX, MTPAD-M)
................ 8
12.
Programming in double security mode (LCSP)
........................................... 9
• Programmable trough readers
• 4000 users (Cards)
• 2 reader inputs (Auto detect Wiegand26 / Wiegand34)
• 2 door relays (2 x 250VAC/4A)
• 2 door sensor inputs
• 2 push button inputs
• 2 Alarm relays: Output 1 (door forced alarm), Output 2
(door left open alarm)
• Programming done with Master1&2, Delete, Reset APB,
Master 1 and Master 2 card
• Adjustable Door relay time (1 - 250sec, or ON/OFF(toggle)
mode)
• Anti Pass Back option
• Normal wiegand mode (card only) and LCSP mode (card and
PIN code) on any reader
• Shadow delete card - per user or per group of users
• Max. Users in 1 groups: 4000 (each group has 1 card)
• Single door mode / 2 readers (one reader on each side of the
door)
• 2 door mode / 2 readers (one reader on each door)
• 60 sec lockout after 15 invalid cards
• Enroll sequential block of cards - max. block of 100 cards
Electrical Characteristics
Operating Voltage:
8 to 15V DC
Current consumption : max. 180 mA (without readers)
Door Relays:
250 VAC/4A
Output Relays:
250 VAC/4A
Environmental Characteristics
Operating Temperatures :
0ºC to +50ºC
Operating Humidity :
0 to 95% (non-condensing)
PCB Dimensions (mm) 102 L x 86 W
90 m
m
107 m
m
61
m
m
v.b2