EN-14 C4S_R_TS_TR_PS_PR_HTS_HTR_gb · 07/15/A
www.dimplex.de/en
Englis
h
C4S, C4R, C4TS, C4TR, C4PS, C4PR, C4HTS, C4HTR
Fig. 6: Wiring and configuration C4S, C4R, C4PS, C4PR
Fig. 7: Wiring and configuration C4TS, C4TR
Fig. 8: Wiring and configuration C4HTS, C4HTR
Fig. 9: Adjusting the humidity setting
Fig. 10: Adjusting the run on timer setting
NOTES
Factory settings: Timer 15 minutes, RH 75%
6.2 Using the fan
Model C4S/C4R
Operate the fan using the on/off switch (not sup-
plied). Repeat to switch off.
Model C4PS/C4PR
Operate the fan by pulling and releasing the cord.
Repeat to switch off.
Model C4TS/C4TR
Operate the fan using an on/off switch (not sup-
plied). When the switch is turned off, the fan contin-
ues to operate for the set time delay. To adjust the
over-run period, turn the control “T” clockwise to in-
crease and anti-clockwise to decrease – see Figure
7a.
Model C4HTS/C4HTR
Automatic mode
- The fan automatically adjusts to
slow changes in natural humidity levels without op-
erating the fan. If the humidity levels increase at a
rate slower than 5% RH in 5 minutes, up to the pre-
set humidity level, the fan will not be triggered by
humidity. This is to prevent nuisance triggering of
the fan. If humidity levels increase quicker than 5%
RH in 5 minutes the fan will operate. When relative
humidity drops the fan continues to operate for the
adjustable time delay.
External operation
- Use the external on/off
switch. When the fan is switched off, the fan contin-
ues to operate for the adjustable time delay then
goes into automatic mode.
Set jumper to required
Customer
high low
speed
position for speed setting
onnection
terminal
Customer
connection
Set jumper to required
position for speed setting
high
speed
low
speed
terminal
high
speed
low
speed
Hygrostat
over-run
Set jumper to
required for
Customer
connection
imer
speed setting
terminal
Fan switches on
at lower level of
condensation
(anti-clockwise)
More sensitive
RH = 50%
Fan does not
switch on until
higher level of
condensation
(clockwise)
Less sensitive
RH = 95%
Fan runs on for a
longer time when
the external switch
is turned off.
Minimum
30 seconds
.
Fan runs on for a
longer time when
the external
switch is turned
off.
Maximum
30 minutes