www.dimplex.de/en C4S_R_TS_TR_PS_PR_HTS_HTR_gb · 07/15/A
EN-13
English
C4S, C4R, C4TS, C4TR, C4PS, C4PR, C4HTS, C4HTR
5.3 Mark the position of the back-plate
Hold the back-plate so that the level line marked on
it is orientated horizontally.
Carefully insert the fan tube into the wall duct.
Mark on the wall the positions of the fixing holes in
the back-plate. (See Fig.3)
Remove the back plate from the ducting.
Drill screw holes in these positions if necessary, and fit
wall plugs and screws as required. The fan may also be
fixed to a wall tube using the clamping brackets.
Fig.
3:
Back plate fixing positions
NOTES
If installing in a ceiling, appropriate termination
ancillaries are required. Follow instructions provided.
5.4 Mount the back-plate
Feed the mains cable through the cable entry hole
in the back plate to the terminals.
Insert the fan tube of the back-plate into the wall
duct/ceiling as before.
Fasten the back-plate to the wall/ceiling using ap-
propriate fastener.
If using screws, do not over tighten. The fan may also
be fixed to a wall tube using the clamping brackets.
Tighten the screws until the fan is firmly secured to the
tube – see figure 4.
Fig.
4:
Wall tube quickfix clamps
5.5 Electrical connection
ATTENTION!
Check that the electrical rating shown inside the back-
plate matches your mains supply
Make sure the mains supply is isolated. Switch off
the mains electrical supply and remove fuses.
Feed the cable to the terminal block. Wire the fan
as shown in Figure 5 using the diagram appropriate
to the fan model.
Connect the cable from the isolating switch to the
electrical supply wiring
.
Fig. 5: Electrical connection / Wiring diagram
ATTENTION!
For fixed wiring circuits the protective fuse for the
appliance must not exceed 5A.
6
Fan Settings
6.1 Speed Setting
The fans are factory set to low speed, but have two
speed settings for different applications. Select either
high or low speed by connecting the jumper between
the centre and high or low speed pin on the jumper
(see Figure 6, 6a, 6b).
Model C4TS/C4TR – Figure 7a
To adjust the over-run period turn the control (T)
clockwise to increase and anti-clockwise to de-
crease
Model C4HTS/C4HTR – Figure 7, 7a
The pre-set humidity operation is factory set at ap-
proximately 75% Relative Humidity (RH), but can
be adjusted between 65% and 85% RH by control
H.
The over-run timer is factory set at 15 minutes but
can be adjusted from 30 seconds to 30 minutes by
control T.
Turn the controls clockwise to increase RH or time
and anti-clockwise to decrease.