Segment no.1 speed
Segment no.2 speed
Segment no.3 speed
Segment no.4 speed
Segment no.1 speed
Segment no.2
changed speed
Segment no.2 speed
Segment
no.3 speed
Segment no.4 speed
Segment no.1
pulse
Segment no.2
pulse
Segment
no.3 pulse
Segment no.4
pulse
Segment no.2
pulse
Segment
no.3 pulse
Segment no.4
pulse
Segment
no.1 pulse
The speed changed
The speed did not
change
◆
the motor running diagram in incremental position mode
0
Starting point
5000
15000
21000
46000
Segment no.1
positive pulse
Segment no.2 positive pulse
Segment no.3 negative pulse
Segment no.4 positive pulse
41000
End position
Incremental position mode
Present pulse/
position
the present position is 5000, in the incremental position mode, the first segment sends 10000
pulses, the motor will go to the position of 15000 pulses; the second segment sends 26000 pulses,
the motor will go to the position of 41000 pulses; the third segment sends -20000 pulses, the
motor will reverse go to the position of 21000 pulses; the fourth segment sends 25000 pulses, the
motor will go to the position of 46000 pulses.
◆
the program in incremental position mode: