33
3: speed (terminal command)
4: speed (analog)
5: position (internal)
6: position (pulse)
7: speed (pulse)
02
Sub-mode 2
0~7 ditto
-
0
0
~
7
○
03
Modbus station no. of COM2
-
1
1
~
255
●
04
Parameters of COM2
-
n.2206
n.0000
~
n.2209
●
05
Rotation direction
0: look at load side, counterclockwise
is forward.
1: look at load side, clockwise is
forward.
-
0
0
、
1
●
06
06.L: stop mode when servo OFF or
alarm. DS2 is inertia stop. Keep
inertia state after stop.
-
2
0
~
2
●
06.H: stop mode when over range
0~1: inertia stop. Keep inertia state
after stop.
2: deceleration stop. Change to zero
clamp state after stop. Torque value:
P4-06 urgent stop torque
3: deceleration stop. Change to inertia
motion after stop. Torque value:
P4-06 urgent stop torque.
-
2
0
~
3
●
Содержание DS2-20P2-AS
Страница 1: ...Wuxi Xinje Electric Co Ltd DS2 series servo drive Manual Data No SC209 20110412 1 0 ...
Страница 2: ...2 ...
Страница 13: ...11 Type LA Normal With brake MS 60ST M01330 20P4 146 189 ...
Страница 14: ...12 80 series motor installation dimensions Unit mm Type LA Normal With brake MS 80ST M02430 20P7 150 191 ...
Страница 16: ...14 Wiring 1 Main circuit ...
Страница 48: ......