(4) Installation
Follow the procedure below to install multiple servo drivers side by side in a control
panel.
Servo drive direction
Install the servo driver perpendicular to the wall and make the front panel towards
operator.
Cooling
Please leave enough space as the above diagram to ensure cooling by fans or
natural ventilation.
Side-by-side installation
As the above diagram, leave min 10cm space at horizontal direction, leave min
50mm space at vertical direction. Install cooling fans above the drive. Keep the
uniform temperature inside the control panel to avoid overheat at local place.