background image

 

1. Product introduction 

1-1. Model naming rule 

Take DP3F-705 as an example: 

DP3F  -  70  5

② ③

 

 

: DP3F series closed loop stepping driver 

 

: Driver output maximum peak current 7A 

 

: The maximum supply voltage of the driver is 50VDC 

 

1-2. Performance 

 

The encoder is used as position feedback, which can compensate the position deviation in real time, and 

solve the problem of losing step of traditional stepping motor 

 

The current can be adjusted in real time according to the load and speed, so that the operation is more 

stable and the motor heating is lower 

 

Compared  with  the  open-loop  stepping,  the  high-speed  performance  of  the  motor  is  significantly 

improved 

 

The pulse and direction input voltage supports 5V and 24V, which can be set by sliding switch 

 

4-bit DIP switch, 16 levels subdivision can be set to meet the needs of most customers 

 

The rotation direction of the motor can be changed by switch 

 

It has power on auto-tuning function, can be set by switch 

 

It supports single and double pulse mode, can be set by switch 

 

Support smoothing time, can be set by switch and convenient for debugging and improves the stability 

of motor operation 

 

Two digital input signals: enable signal input and alarm clear signal input 

 

Three digital output signals: alarm signal output, in place /Z signal output, brake signal output 

 

It  has  over-current,  over-voltage,  rotation  blocking  detection,  out  of  step  compensation  and  other 

protection functions 

 

1-3. Application field   

It is suitable for all kinds of small and medium-sized automation equipment and instruments, such as engraving 

machine, stripping machine, marking machine, cutting machine, laser machine, plotter, medical equipment, CNC 

machine tool, automatic assembly equipment, electronic processing equipment, etc. 

 

1-4. Electric features 

Model   

DP3F-305 

DP3F-705 

DP3F-808 

Input power supply (VDC) 

20~50 

20~50 

20~80 

Output peak current (A) 

1~3 

1~7 

1~8.4 

Matched motor (base) 

42 

57/86 

86 

Step pulse frequency (KHz) 

24V signal 200K, 5V differential signal 500K 

Control signal input voltage (VDC) 

5/24 (Sliding switch setting) 

Содержание DP3F Series

Страница 1: ...1 DP3F series closed loop stepping driver User manual Wuxi Xinje Electric Co Ltd Data No D3C05 202001215 1 0...

Страница 2: ...nual Statement of responsibility Although the contents of the manual have been carefully checked errors are inevitable and we can not guarantee that they are completely consistent We will always check...

Страница 3: ...iagram 7 2 2 2 Wiring notice 7 3 DRIVER INTERFACE 8 3 1 STATUS INDICATOR AND TROUBLESHOOTING 8 3 2 UPPER COMPUTER COMMUNICATION INTERFACE 8 3 3 CONTROL SIGNAL INTERFACE 9 3 3 1 Function 9 3 3 2 Contro...

Страница 4: ...g function can be set by switch It supports single and double pulse mode can be set by switch Support smoothing time can be set by switch and convenient for debugging and improves the stability of mot...

Страница 5: ...sional technicians 2 The input voltage of the driver must meet the technical requirements 3 It is strictly forbidden to plug the strong current terminal of the driver when the power is on When the mot...

Страница 6: ...6 2 Installation and wiring 2 1 Installation 2 1 1 Outline dimension DP3F 305 DP3F 705 Unit mm 31 77 110 102 6 4 21 8 5 2 4 3 4 3 DP3F 808 Unit mm 35 5 86 7 135 127 9 25 3 4 3 4 3 3 8 5 2...

Страница 7: ...pulse and direction signal cables and motor cables are not allowed to be bound side by side and it is better to separate them at least 10cm otherwise it is easy to interfere with the pulse direction s...

Страница 8: ...it 2 Over voltage Check whether the power supply voltage is too high 3 Under voltage Check whether the power supply voltage is too low 4 Motor open circuit or poor contact Check whether the power cabl...

Страница 9: ...he upper computer according to the demand The rising edge is valid by default Note the input of 24V signal will damage the input terminal when 5 V is selected PUL DIR Direction control signal DIR ENA...

Страница 10: ...ol signal circuit Control signal input and output circuit diagram as shown in the figure below Differential mode input Input single ended common anode connection method Input single ended common catho...

Страница 11: ...gnal 3 5 Motor and power supply interface 3 5 1 Strong current interface function Interface Function Explanation A A Motor phase A coil Cannot change direction by exchanging A A B B Motor phase B coil...

Страница 12: ...y is used the switching power supply output current range should be set to the maximum Note 1 Do not reverse the power supply voltage 2 Do not exceed the working range of the power supply to ensure th...

Страница 13: ...y upper computer 4000 On On On On 800 Off On On On 1600 On Off On On 3200 Off Off On On 6400 On On Off On 12800 Off On Off On 25600 On Off Off On 51200 Off Off Off On 1000 On On On Off 2000 Off On On...

Страница 14: ...et by the upper computer default 1 5ms ON ON 3ms ON OFF 12ms OFF ON Shut down the filter OFF OFF 4 2 5V 24V switch DP3F can select the 5V 24V pulse and the direction input level through this switch Th...

Страница 15: ...Internal pulse 0 1 0 Internal pulse operation mode 0 external pulse 1 internal pulse P0 05 0x0005 Open loop current percentage 1 100 50 Operating current in open loop mode Percentage of open loop cur...

Страница 16: ...rs Parameter Address Function Range Default Note P3 00 0x0300 Tracking error limit 1 65535 4000 1 turn P3 01 0x0301 Fault detection selection 0 65535 255 P3 02 0x0302 Under voltage alarm threshold 0 2...

Страница 17: ...P7 00 0x0700 Driver station no 1 100 1 P7 01 0 0x0701 0 1 Baud rate 03 2400 04 4800 05 9600 06 19200 07 38400 08 57600 09 115200 0A 192000 0B 256000 0C 288000 06 Default 19200bps 1 stop bit even parit...

Страница 18: ...phase feedback current mA U0 27 0x101B B phase feedback current mA U0 28 0x101C Reference feedback current mA U0 29 0x101D A phase set current mA U0 30 0x101E B phase set current mA U0 31 0x101F Refer...

Страница 19: ...06 Firmware generation date Day U2 07 0x1207 Software version U2 08 0x1208 Hardware version U2 09 0x1209 Power on operation time Hour U2 10 0x120A Power on operation time Minute U2 11 0x120B Power on...

Страница 20: ...on again Release signal is low Do not connect this signal Not power on Power on again Motor wiring error Check the wiring No pulse signal input Check the pulse cable and signal voltage Motor directio...

Страница 21: ...WUXI XINJE ELECTRIC CO LTD 4th Floor Building 7 Originality Industry park Liyuan Development Zone Wuxi City Jiangsu Province 214072 Tel 400 885 0136 Fax 510 85111290 www xinje com...

Отзывы: