Installation Guide for C3-X60 Series Control Panel
3.5 Connection with External Accessories
1. Door sensor
A door sensor is used to detect the open/closed status of a door. With a door sensor
switch, an access control panel can detect illegal opening of a door, and will trigger
an alarm. Moreover, if a door is not closed within a specified period of time after it
is opened, the door control panel will also prompt an alarm. It is recommended to
select two-core wires over 0.22 mm
2
. A door sensor may be omitted if it is unnecessary to
monitor online the open/closed status of a door, trigger an alarm when the door is not
closed for a long time or there is illegal access, and use the interlock function.
2. Exit button
An exit button is a switch installed indoors to open a door. When you press the
button, the door will be opened. An exit button is fixed at a height of about 1.4
meter above the ground. Ensure it is located in the right position without slant, and
its connection is correct and secure (Cut off the exposed end of any unused wire
and wrap it with insulating tape). Note to prevent the electromagnetic interference
(such as light switches and computers). It is recommended to use two-core wires over
0.3mm
2
as the connection wire between an exit button and a control panel.
3. Auxiliary input
C3-160 provides one auxiliary input interface; C3-260 provides two, and C3-460
provides four, which are connected to infrared body detectors, smoke detectors, gas
detectors, window sensor alarms, wireless exit buttons, etc. Auxiliary inputs are set
through relevant access control software. For details, please refer to
ZKAccess5.0
User Manual.