Installation Guide for C3-X60 Series Control Panel
In use of inBIO reader, all operations including storage, verification, etc. execute in
control panel. No need to re-register the fingerprints for reader changing. Realize
the real biometric reader connection.
1. Connected with inBIO readers
C3-160 can connect two inBIO readers in the one-door two-way mode. C3-260
provides four readers, which can be connected in the two-door two-way mode.
C3-460 provides eight readers, which can be connected in the two-door two-way or
four-door one-way mode.
485 reader connection: First of all, set the 485 address (device number) of reader by
software, DIP switch or keypad method. Such as the reader 1, 2 (the odd number is
for enter reader, and the even number is for exit reader), for example, the 485
address is 1, 2, and the door number is 1. For more information, please refer to the
software user manual.
Connection between C3-460 and inBIO Readers
2. Connected with Wiegand readers
C3-160 can connect two Wiegand readers in the one-door two-way mode. C3-260
provides four readers, which can be connected in the two-door two-way mode.
C3-460 provides four readers, which can be connected in the two-door two-way or
four-door one-way mode.
The Wiegand interfaces provided by the C3 series can be connected to different
18