Embedded Tri-Mode Ethernet MAC User Guide
91
UG074 (v2.2) February 22, 2010
Host Interface
R
The IRENABLE register (Address Code
0x3A4
) in the host interface is used to enable
interrupt bits in the IRSTATUS register. To enable an interrupt, the corresponding bit is set.
When the enable bit is cleared, the interrupt status is not updated.
For examples of DCR read and write accesses, see
“Interfacing to the Processor DCR” in
.
Address Code
The address codes for the Ethernet MAC registers are divided into three groups as shown
in
. The unused address codes are reserved. The detailed address codes for each
register are described in
. The address codes for the Ethernet MAC registers and
registers in the host interface are encoded in hardware. Address codes for statistics IP
registers and Ethernet MAC Configuration registers match the 1G Ethernet MAC Host Bus
address as specified in the Xilinx® 1G Ethernet MAC core at:
http://www.xilinx.com/support/documentation/ip_documentation/gig_eth_mac_ds200.pdf
.
Table 3-29:
Address Code Groups for DCR Host Bus Access
Group
Address Code
Description
EMAC0
0x200
–
0x39F
EMAC0 registers.
Host Interface
0x3A0
–
0x3FF
Host interface registers.
EMAC1
0x600
–
0x79F
EMAC1 registers.
Notes:
1. Any access to the host interface registers does not generate interrupts and does not change the
RDYSTATUS register bits.
Table 3-30:
Detailed Address Codes for DCR Host Bus Access
Address
Codes
Register Names
Description
Ethernet MAC
Register Address
R/W
0x0:0x1FF
Reserved.
EMAC0 Registers:
0x200
E0_RXCONFIGW0
Receiver configuration word 0.
0x200
R/W
0x240
E0_RXCONFIGW1
Receiver configuration word 1.
0x240
R/W
0x280
E0_TXCONFIG
Transmitter configuration.
0x280
R/W
0x2C0
E0_FLOWCONTROL
Flow control configuration.
0x2C0
R/W
0x300
E0_EMACCONFIG
Ethernet MAC configuration.
0x300
R/W
0x320
E0_RGMII_SGMII RGMII/SGMII configuration.
0x320
R
0x340
E0_MGMTCONFIG
Management configuration.
0x340
R/W
0x380
E0_UNICASTADDRW0
Unicast address [31:0].
0x380
R/W
0x384
E0_UNICASTADDRW1
0x0000
, unicast address [47:32].
0x384
R/W
0x388
E0_ADDRTABLECONFIGW0
Multicast address data [31:0]
0x388
R/W
0x38C
E0_ADDRTABLECONFIGW1
0x00,
RNW,
00000
, ADDR[1:0],
Multicast address data [47:32]
0x38C
R/W
www.BDTIC.com/XILINX