Xilica Audio Design neutrino series Скачать руководство пользователя страница 7

 

 

The primary difference between these two connection methods is the automatic IP address 
assignment that DHCP provides in 

(A)

(A)

 

DHCP Enabled Router, Server, or Router/Server/Switch Combo Connection

   

                            

The Neutrino processor device boots up with DHCP enabled by default so with DHCP 
enabled routers and servers Neutrino will automatically obtain an IP address upon power up 
and connection.  This may take a minute or two as the devices look for DHCP to obtain their 
IP address.

 

Available DHCP is the recommended connection method.

  Where our NeuPanel Series 

wall controls will be used to control the processor we recommend the use of a low cost 
router along with a POE switch.  This combo will provide 

DHCP

 as well as power to the wall 

controls over their Ethernet cable by way of the switches 

POE

 feature (Power Over Ethernet).     

Note:

  Linksys routers/NetGear switches have tested well (D-Link routers have not).  

 

(B)

 

Non-DHCP Enabled Direct or Indirect Connection 

When the processor is connected directly to a computer or indirectly via a switch or hub and 
DHCP is not available to assign IP addresses - the connection process is not automatic.   

 
(1)

 

A Single Processor or Device in the Network Only - No DHCP Available 

Once no DHCP is detected - a single direct or indirectly connected processor device will 
either try to connect using the IP address last assigned and stored in the device or 
attempt to revert to is default IP address of 169.254.128.128.  Under some conditions 
the processor might refuse to relinquish its stored IP address or revert to its default IP 
address and thus refuse to connect.  

To simplify and speed this non-DHCP enabled 

connection we recommend

 - that before you power up your device you should 

Reset

 

the processor to its 

Default IP Address

 using the 

IP Reset Button

 on the rear of the 

processor.  Resetting the processor to its default IP address of 169.254.128.128 will have 
you connecting directly quickly and without problems when no DHCP is available.   
Please see

 

-

 

IP Reset Push Button / Reset Processor Network Settings

 

instructions 

below.          

Содержание neutrino series

Страница 1: ...NEUTRINO Product Quick Start Guide...

Страница 2: ...prong The wide blade or the third prongs are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 PROTECT THE P...

Страница 3: ...3 Getting Help The included NeuConsole software the Windows software that configures controls the Neutrino processor includes a Help File That help file provides a detailed User Manual software and h...

Страница 4: ...the processor Proper Network Connection and Operation is indicated displayed only in the software s Network View page see the Network View Connection section of this guide b When the processor and so...

Страница 5: ...ets within NeuConsole or control external devices like an electric screen for example 7 Analog Line Outputs Euro Phoenix style terminal block output connections utilizing 3 5mm terminal block connecto...

Страница 6: ...on Simply un install the old NeuConsole software version in Control Panel before you update your software version each time You won t have any update issues and you won t have to remember what locatio...

Страница 7: ...ct or Indirect Connection When the processor is connected directly to a computer or indirectly via a switch or hub and DHCP is not available to assign IP addresses the connection process is not automa...

Страница 8: ...ress When complete the Network LED Data LED on older models will light and remain on Note Some Uno processors were manufactured with a different IP Reset switch that was hidden behind a removable cove...

Страница 9: ...connect to a single processor or multiple processors where DHCP is not available d When the processor and software are connected and commands are being sent to the device the blue Network status LED D...

Страница 10: ...the device is connected online but Not Ready Not Operational a The three most common reasons for this Yellow connection indicator is the result of 1 A non DHCP connection where multiple processors ar...

Страница 11: ...addresses are required for each processor device Computer set to Obtain IP Address Automatically We will set your computers static IP address after setting each processor or device To manually assign...

Страница 12: ...IP Address 192 168 1 X Example IP might be 192 168 1 185 based on my Subnet Mask 255 255 255 0 unique device addresses above Gateway 192 168 1 1 DNS Servers 192 168 1 1 g If you set up your devices as...

Страница 13: ...rder to begin a new DSP design project as shown at right If you have just opened the software from the NeuConsole Startup window you can select New Design Project in order to begin a new DSP design pr...

Страница 14: ...ading and the category headings of Neutrino Processors Control Devices and DSP Modules The Component Properties menu on the right side of the Project View work area provides the means to alter the spe...

Страница 15: ...no processor As shown below on Page 14 b As shown below we have added source and playback audio components We are able to label the Neutrino processor and audio components as well as connecting cable...

Страница 16: ...the drop down list as shown at right c As shown below on Pg 15 once mapped you will notice that the software processor module in the Project View Design Mode work area has turned from light see throug...

Страница 17: ...er DSP Modules on the left drag and drop a Matrix Mixer onto the schematic design work area Click on the grey dotted DSP schematic design page to open the Components Library and the list of DSP module...

Страница 18: ...m the Input module to the Matrix Mixer You can name the source and destination labels of each DSP modules inputs outputs by pointing at and clicking on a wire and typing in the label name under the ap...

Страница 19: ...w and Device Schematic Design to JPEG files for documentation purposes See the Print Project to JPEG File printer symbol button to the right of the Zoom slider at the top right DSP Module Parameters O...

Страница 20: ...matrix Here input sources are assigned to any or all outputs Ensure that Input 1 routes to Output 1 Input 2 to Output 2 and so on as shown at right The Connect button ensures that the signal routes t...

Страница 21: ...ng with the Work File or a file name of choice and the Master File is protected should you ever need it At the end of the project continue running the system with the Work File rename it to Master Ver...

Страница 22: ...rdware and software are in Online Mode c Note that when the red processor module is visible as it is above that the processor device model has a green indicator beside it to indicate that the processo...

Страница 23: ...From the software NeuConsole Startup window Select Open Design Project and select and open the specific DSP design project saved in your PC pjxml files Or From the Network View or Project View window...

Страница 24: ...g to Online Mode from Design Mode if you answer No to permissions the processor is not loaded with the saved project file and thus any changes to the processor settings made in Open Device mode are vi...

Страница 25: ...detailed operational guidance regarding Presets and other topics please see the detailed User Manual that can be viewed in the NeuConsole software Help File information on the USB drive packaged with...

Страница 26: ...upport xilica com and we ll connect you with a solutions engineer Alterna tively if you d like to speak to someone you can call the following numbers for immediate assistance North America Rest of Wor...

Отзывы: