XES Synergix 8825/8830/8850/8855 & X2-TECH System Introduction
29
Quick Start for Plot Nesting (continued)
Setting Nesting Parameters with the
8825/8830/8850 Printer Control Panel
•
Press
on the Control Panel to take the printer off-line. Press
Enter
.
•
Press
the
Next
key until SETUP PRINTER is displayed. Press the
Enter
key to confirm the choice.
•
Press
the
Next
key until PLOT NESTING is displayed. Press the
Enter
key to confirm the choice.
•
Press
the
Next
key until MODE ENABLE is displayed. Either accept the
factory default setting of OFF, or press the
Enter
key to change the
setting.
Use the
Next
key to select ON or OFF.
Press the
Enter
key to confirm the choice and the
Exit
key to return to
the PLOT NESTING menu.
•
Press
the
Next
key until EXCLUSIVE ENABLE is displayed. Either
accept the factory default setting of OFF, or press the
Enter
key to
change the setting.
Use the Next key to select ON or OFF.
Press the
Enter
key to confirm the choice and the
Exit
key to return to
the PLOT NESTING menu.
•
Press
the
Next
key until TIMEOUT is displayed. Either accept the factory
default setting of 5, or press the
Enter
key to change the setting.
Input a Plot Nesting Timeout between 5 and 300 seconds using the
numeric keypad.
Press the
Enter
key to confirm the choice and the
Exit
key to return to
the PLOT NESTING menu.
•
Press
the
Next
key until MARGIN is displayed. Either accept the factory
default setting of zero (0), or press the
Enter
key to change the setting.
Input the Plot Nesting Margin using a number between 0 and 25
millimeters using the numeric keypad.
Press the
Enter
key to confirm the choice and the
Exit
key to return to
the PLOT NESTING menu.
•
Press
the
Next
key until MAXIMUM LENGTH is displayed. Either accept
the factory default setting of 61 centimeters, or press the
Enter
key to
change the setting.
Input a Plot Nesting maximum length between 21 and 2438 centimeters
using the numeric keypad.
Press the
Enter
key to confirm the choice and the
Exit
key to return to
the PLOT NESTING menu.
•
Press
on the Control Panel to put the printer back on-line.