Xerox® Phaser® 3052/3260 Service Manual
Voltage Specifications
Introduction
5.
Test Point, Test Hole, Test Stake
•
This symbol is used to indicate that a test point, test hole, or test stake is available
for accessing the signal line. The prefix indicates whether the access is a test point
(TP), test hole (TH), or test stake (TS).
6.
Commoning Point
•
This symbol is used to refer to a location in the machine wiring where more than two
wires a connected together at a single point.
7.
Arrow
•
This symbol points to the location to install, gain access to, or to release a compo-
nent.
Voltage Specifications
AC and DC Voltages
Measurements of DC voltage must be made with reference to the specified DC Common,
unless some other point is referenced in a diagnostic procedure. All measurements of AC volt-
age should be made with respect to the adjacent return or ACN wire (
Table 1
).
Logic Voltage Levels
Measurements of logic levels must be made with reference to the specified DC Common,
unless some other point is referenced in a diagnostic procedure (
Table 2
)
DC Voltage Measurements in RAPs
The RAPs have been designed so that when it is required to use the DMM to measure a DC
voltage, the first test point listed is the location for the red (+) meter lead and the second test
point is the location for the black meter lead. For example, the following statement may be
found in a RAP:
There is +5 VDC from TP7 to TP68.
In this example, the red meter lead would be placed on TP7 and the black meter lead on TP68.
Another example of a statement found in a RAP might be:
There is -15 VDC from TP21 to TP33.
In this example, the red meter lead would be placed on TP21 and the black meter lead would
be placed on TP33.
If a second test point is not given, it is assumed that the black meter lead may be attached to
the copier frame.
Table 1 Voltage Measurement and Specifications
VOLTAGE
SPECIFICATION
110 to120 VAC 60Hz
100 to 132 VAC
Neutral to Ground VAC
0 VAC (+/- 5VAC)
+5 VDC
+5.05 VDC TO +5.25 VDC
+12 VDC
+11.4 VDC TO +12.6 VDC
-12 VDC
-11.4 VDC TO -12.6 VDC
+24 VDC
+22.8VDC TO +25.2 VDC
+36 VDC
+34.2 VDC TO +37.8 VDC
Table 2 Logic Levels
VOLTAGE
H/L SPECIFICATIONS
+5 VDC
H= +3.00 TO +5.25 VDC, L=
0.0 TO 0.8 VDC
+24 VDC
H= +23.37 TO +27.06 VDC,
L= 0.0 TO 0.8 VDC
Содержание Phaser 3052
Страница 1: ...Xerox Phaser 3052 3260 Service Manual 702P02830 June 2014 Initial Issue ...
Страница 2: ......
Страница 4: ...June 2014 2 Xerox Phaser 3052 3260 ...
Страница 6: ...June 2014 ii Xerox Phaser 3052 3260 Service Manual Introduction ...
Страница 18: ...June 2014 1 2 Xerox Phaser 3052 3260 Service Manual Service Call Procedures ...
Страница 24: ...June 2014 2 2 Xerox Phaser 3052 3260 Service Manual Status Indicator RAPs ...
Страница 42: ...June 2014 3 2 Xerox Phaser 3052 3260 Service Manual Image Quality ...
Страница 51: ...June 2014 3 11 Xerox Phaser 3020 Printer Service Manual IQ11 Image Quality Figure 1 Image Deletions ...
Страница 52: ...June 2014 3 12 Xerox Phaser 3020 Printer Service Manual IQ11 Image Quality ...
Страница 54: ...June 2014 4 2 Xerox Phaser 3052 3260 Service Manual Repairs ...
Страница 100: ...June 2014 4 48 Xerox Phaser 3052 3260 Service Manual REP 1 26 REP 1 27 Repairs ...
Страница 102: ...June 2014 5 2 Xerox Phaser 3052 3260 Service Manual Parts List ...
Страница 118: ...June 2014 6 2 Xerox Phaser 3052 3260 Service Manual General Procedures and Information ...
Страница 130: ...June 2014 6 14 Xerox Phaser 3052 3260 Service Manual GP 7 GP 8 General Procedures and Information ...
Страница 134: ...Xerox Phaser 3052 3260 Printer Service Manual June 2014 BSDs THIS PAGE INTENTIONALLY BLANK ...