7-29
Setup Menus
NCSI Settings
This TeemTalk for Windows 3.1x dialog box is displayed by clicking the
Configure...
button in the
New Connection
dialog box when the connection
type is set to
Extended NCSI
.
Baud Rate
Factory default: 9600
This specifies the transmit and receive baud rates in the range 50 to 115200 baud.
Parity
Factory default: None
This option specifies the parity mode for each transmitted character.
If the number of
Data Bits
is
8
, set this option to
None
.
Selecting
Odd
will cause an eighth bit to be added with a value of 1 if the previous 7
bits add up to an even number, and 0 if the previous 7 bits add up to an odd number.
Selecting
Even
will cause an eighth bit to be added with a value of 1 if the previous 7
bits add up to an odd number, and 0 if the previous 7 bits add up to an even number.
Mark
parity will set every eighth bit to 1 and
Space
parity every bit to 0.
Flow Control
Factory default: Xon/Xoff
This option specifies the type of flow control used to communicate readiness to
transmit or receive data from the host. It can be set to
None
,
DTR
,
RTS
,
DTR/RTS
or
Xon/Xoff
.
Содержание -05W
Страница 1: ...TeemTalk 05W 07W 11W User s Guide...
Страница 38: ...2 24 Getting Started Notes...
Страница 58: ...3 20 Keyboard Configuration Notes...
Страница 152: ...8 20 File Transfer Notes...
Страница 162: ...9 10 ICL FTF File Transfer Notes...
Страница 324: ...13 32 Dynamic Data Exchange Text1 i 12 LinkItem 0 i 80 Text1 i 12 LinkMode 1 Next i End If End Sub...
Страница 336: ...C 6 Key Reference Numbers Notes...
Страница 360: ...E 16 Host Command Summary Notes...
Страница 370: ...Index 10 Index X XMODEM 8 1 XMODEM 1K 8 1 Y YMODEM Batch 8 2 Z ZMODEM 8 2 Zoom Button 2 17...