18
EN
STAND-ALONE
(no users present during the charge process)
Put the charger in set-up mode, as described earlier.
A ‘0’ will appear in the display screen. By way of pressing on the ‘mode’ button it is
possible to switch between the green and the red led. Adjust the charger as per the
red
led.
After this wait for 10 seconds.
A number will now appear in the display screen which indicates the charging program.
By way of repeatedly pressing the ‘mode’ button it is possible to enter the correct
charging program which corresponds to the battery type.
Battery type
Suggested program
GEL, AGM(1)
CALCIUM, AGM(2), SPIRAL
OPEN SEMI-TRACTION
TRACTION
After this wait for 10 seconds.
A ‘t’ will appear in the display screen. Now it is possible to determine if the optional
temperature sensor has been connected. By way of pressing the ‘mode’ button it is once
again possible to switch between the green and red led.
Temperature sensor
Set the LED to
green
present
Temperature sensor
isn’t present
Set the LED to
red
.
(factory setting)
No
Yes
Heavy cyclic use?
(comp. phase on?