73
72
Settings >> Alarms >> dive time
This function sets the dive time alarm.
Settings >> Alarms >> Max. depth
This function sets the maximum dive depth alarm. The alarm will be activated
each time the current depth exceeds the set value.
Settings >> Alarms >> Average depth
This function sets the average dive depth alarm. The alarm will be activated
each time the current depth exceeds the set value.
Settings >> Alarms >> Battery
This function sets the battery charge level at which the device will activate
the alarm. This alarm is active in addition to the basic battery alarm which is
always displayed when battery charge level drops to 20%.
SETTINGS – ALARMS 1/2
attention! Due to safety reasons changing the gas parameters
(O2 and He concentration) whilst on a dive for a gas that you
are breathing will nOT update automatically the gas parameters
used for decompression and nDl calculation. Only when that gas
is switched to again will the device take into account the new
values of O2 and He parameters. In order to prevent mistakes we
strongly recommend not to adjust the parameters of a gas whilst
you are breathing it!
attention! BlaCK eanX will not accept fractional percentage val-
ues of oxygen concentration. never round up the fraction of the
oxygen. If the oxygen content measured with the use of analyser
is fractional, you must round it down. as an example, when the
measured oxygen content amounts to 21.7% it is necessary to
round it down to 21%.
SETTINGS – LIST OF BREATHING GASES
3/4
Содержание BLACK EANX
Страница 1: ...User s manual OLED DIVE COMPUTER Firmware version 2 9 3...
Страница 53: ...2015 GENZ ALL RIGHTS RESERVED...