VII.7.1 - Description
VII.7.2 - Solution
The solution above assign the PLC to a technician for a minimum of 3 minutes, even if his
terminal is off.
This solution have all advantages of the two preceeding solutions. Access to the PLC will
be assigned to the first technician who will try to establish the connection. If the technician
power off his terminal, the PLC will be immediatly accessible to the second technician.
One the other hand, if the technician forgets to power off his terminal, the PLC will be
accessible to the second technician after 3 minutes.
On client's side Xcell :
p
Link DTR (or RTS) signal of the terminal to DSR signal of serial port n°1 (make a
cable).
p
Enable redirection of DSR signal to DTR signal of server Xcell (
mux dsrredirect dtr
1).
p
Link DTR signal and DCD signal of serial port n°1 (make a cable).
p
Activate DTR signal of serial port n°1 (
mux defaultdtr yes
1).
p
Configure management of DCD signal by Xcell (
serial linectrl modem
1).
p
Configure Xcell to wait a character before launching the connection (
serial quick no
1).
p
Specify the timeout delay of the unused connection (
serial timeout
180 1).
On server's side Xcell :
p
Link DTR signal and DSR signal of serial port n°1 (make a cable).
-55-